Mechatronics Eurosens Delta CAN 250 Скачать руководство пользователя страница 12

EUROSENS

 

Fuel

 

flow

 

meters.

 

Operation

 

manual.

 

ver.

 

1.6

 

 

www.mechatronics.by

                              

 

 

 

          

Page

 

12

 

|

 

30

 

 

2.8.3.

 

Information

 

screens

 

(flow

 

meters

 

with

 

LCD

 

display)

 

Table

 

9

   

Direct

 

I*

 

Delta

 

I*

 

№ 

Screen

 

Parameter

  

№ 

Screen

 

Parameter

 

1

  

2

  

3

  

4

  

5

  

6

 

7

 

8

 

9

 

10

 

11

 

12

 

Total

 

consumption,

 

l

 

Idle

 

consumption

 

l

   

Consumption

 

under

 

nominal

 

load,

 

l

 

Overload

 

consumption

 

l

  

Cheat

 

consumption,

 

l

 

/

 

h

  

Negative

 

volume,

 

l

 

Total

 

operating

 

time,

  

Hour**

 

Intervention

 

time,

 

hour

 

***

 

Flow

 

rate

  

Chamber

 

temperature,

 

deg.,

 

C

  

 

Battery

 

charge,%

  

Firmware

 

version

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

 

11

 

12

 

13

 

14

 

15

 

16

 

17

 

18

 

19

 

Total

 

consumption,

 

l

 

Idle

 

consumption

 

l

   

Consumption

 

under

 

nominal

 

load,

 

l

 

Overload

 

consumption,

 

l

  

Cheat

 

consumption,

 

l

  

Negative

 

volume

 

,

 

l

  

Total

 

operating

 

time,

  

h

 

**

 

Intervention

 

time,

 

h***

 

Supply

 

flow

 

rate,

 

l

 

/

 

h

  

The

 

total

 

volume

 

of

 

supply,

 

l

  

Cheat

 

volume

 

of

 

supply

 

chamber,

 

l

  

Supply

 

flow

 

rate,

 

l

 

/

 

h

  

Temperature

 

in

 

supply

 

chamber,

 

C

  

The

 

total

 

volume

 

of

 

return,

 

l

  

Cheat

 

volume

 

of

 

return

  

chamber,

 

l

  

Return

 

flow

 

rate,

 

l

 

/

 

h

  

Temperature

 

in

 

return

 

chamber,

 

C

  

Battery

 

charge,

 

%

  

Firmware

 

version

 

*

 

These

 

parameters

 

(plus

 

some

 

additional)

 

are

 

also

 

displayed

 

in

 

configuration

 

software

 

on

 

all

 

flow

 

meters

  

PN

 

(RS)

  

(Eurosens

 

Destination

 

service

 

kit

 

is

 

needed).

 

**

 

for

 

all

 

models,

 

aside

 

Autonomous

 

***only

 

for

 

Autonomous

 

modifications

 

 

2.8.4.

 

 

Cheat

 

protection

 

features.

 

In

 

order

 

to

 

avoid

 

cheating

 

of

 

flow

 

sensor,

 

its

 

damage

 

or

 

blocking

 

Delta

 

and

 

Direct

 

PN,

 

RS

 

models

 

has

 

the

 

following

 

modes

 

of

 

protection

 

against

 

cheating

 

actions

 

of

 

third

 

parties:

  

1)

 

Mode

 

"Cheat"

 ‐ 

protection

 

against

 

cheating

 

in

 

order

 

to

 

increase

 

the

 

counter

 

value

 

of

 

the

 

consumed

 

fuel

 

(eg.

 

air

 

blowing).

 

Cheat

 

usually

 

leads

 

to

 

a

 

rapid

 

increase

 

in

 

fuel

 

consumption

 

that

 

exceeds

 

the

 

maximum

 

one.

 

Electronic

 

circuit

 

board

 

of

 

a

 

flow

 

sensor

 

detects

 

overstated

 

costs,

 

while

 

fuel

 

meter

 

operation

 

is

 

stopped

 

and

 

counter

 

"Cheat"

 

is

 

activated,

 

which

 

records

 

the

 

amount

 

of

 

fuel

 

flown

 

through

 

the

 

flow

 

sensor

 

at

 

high

 

speed.

  

Mode

 

"Cheat"

 

is

 

automatically

 

exited

 

in

 

few

 

seconds

 

after

 

the

 

normalization

 

of

 

conditions

 

of

 

flow

 

sensor

 

work.

  

Содержание Eurosens Delta CAN 250

Страница 1: ...phone 375 1771 7 13 00 e mail office mechatronics by Eurosens flowmeters operation manual...

Страница 2: ...selection 5 2 5 Dimensions 6 2 6 Specification 6 2 7 Contents of package 10 2 8 Flow meter design and operation 11 3 WARRANTY 15 4 INSTALLATION RECOMMENDATIONS FOR EUROSENS FLOWMETER 16 4 1 Visual ins...

Страница 3: ...their operating features The sources of danger during the installation and operation of the flow sensors are electrical current and working fluid which can be pressurized to 2 5 MPa and have temperat...

Страница 4: ...nnormalized pulse only for Direct possible 100 No symbol LCD is not installed Direct 1 PN normalized pulse No symbol not possible 250 232 normalized pulse RS232 interface 500 485 normalized pulse RS48...

Страница 5: ...with the safe operation of the Eurosens sensors on petrol engines are assigned to the installer of the equipment Fuel flowmeters Eurosens Direct Delta N RS is a unique equipment that allows to set ind...

Страница 6: ...commended to install the flowmeter when there is an air in the supply or return line and also in the fuel system with high capacity pomp when the fuel consumption is not large 2 5 Dimensions See para...

Страница 7: ...easure not only the fuel consumption but also the derived parameters the engine is running boiler the fuel consumption and the operating time in different modes during the handling etc These parameter...

Страница 8: ...50 1 5 Delta PN A 100 I 0 5 10 50 100 200 1 2 Delta PN A 250 I 0 5 20 125 250 100 1 2 Delta PN A 500 I 1 0 40 250 500 50 1 5 Flows to supply consumption in liters hour 45 10 90 20 160 30 A autonomous...

Страница 9: ...lta CAN 250 0 5 20 125 250 100 1 2 Delta CAN 500 1 0 40 250 500 50 1 5 Delta CAN 100 I 0 5 10 50 100 200 1 2 Delta CAN 250 I 0 5 20 125 250 100 1 2 Delta CAN 500 I 1 0 40 250 500 50 1 5 Flows to suppl...

Страница 10: ...5 Vibration resistance Max acceleration to 100 m s2 in the frequency range from 5 to 250 Hz Resistance to aggressive environments Oil and petrol resistance Electromagnetic compatibility ECE Regulation...

Страница 11: ...number of dimensions of the cover and the housing which provides the optimum rotation of the ring chamber During one rotation of the piston volume of liquid equal to the volume of chamber is displace...

Страница 12: ...eat volume of return chamber l Return flow rate l h Temperature in return chamber C Battery charge Firmware version These parameters plus some additional are also displayed in configuration software o...

Страница 13: ...ave holes for sealing that allows to determine the facts of unauthorized interference in the fuel system after the installation of the flow sensor 2 8 5 Characteristics of the pulse signal of Eurosens...

Страница 14: ...PH 500 0 9Ubat 0 7 V Direct PN A 100 0 7 Ubat 0 4 1 4 V Direct PN A 250 0 7 Ubat 0 4 1 4 V Direct PN A 500 0 7 Ubat 0 4 1 4 V Delta PN A 100 0 6 Ubat 0 8 0 7 V Delta PN A 250 0 6 Ubat 0 8 0 7 V Delta...

Страница 15: ...ents provided that storage transport and operation conditions are observed and also the instructions for use that set out in this technical requirement are observed as well 2 Product warranty period 3...

Страница 16: ...cle condition should be estimated to make a conclusion regarding installation possibility Table 12 Sequence of actions Action Normal state Recommendations in case of mismatch condition 1 To inspect th...

Страница 17: ...of capacity of the pomp that is installed at the vehicle or by experimental method by connection of fuel flowmeter with display for example Direct PN A I to the scheme 2 It is not recommended to inst...

Страница 18: ...t be protected from external destructive effects 6 It is not allowed to reduce the internal cross section of the fuel lines on the bends 7 Fuel hoses on the vehicle must be fixed every 0 5 m 8 Fuel ho...

Страница 19: ...the engine Excess fuel from the fuel pump and injectors of the engine is discharged back into the tank through relief valve 4 4 2 Installation of fuel flow meters Eurosens Direct On pressure side sch...

Страница 20: ...the amount of fuel which is consumed by engine Advantages of the scheme on pressure side Eurosens Direct is set after the regular fuel fine filter Reduced flow resistance on the supply pump suction si...

Страница 21: ...Thus to the inlet of supply pump two lines are connected 1 supply from the tank passing through the flow sensor 2 The return fuel pump Thus through the flow sensor Direct goes only the amount of fuel...

Страница 22: ...ometimes it is needed to install an additional heater 4 4 4 Installation of Eurosens Delta under Differential scheme In differential scheme the measuring circuit of fuel circulating in the fuel system...

Страница 23: ...ump inlet fuel tank Fig 8 Eurosens Delta installation with supply chamber on pressure side Fig 9 Eurosens Delta installation with supply chamber on suction side Advantages of differential installation...

Страница 24: ...f the vehicle with mandatory fixing with buckles every 50 cm Make electrical connection in accordance to the passport for the product pin circuit Color wires in the cable 1 VBAT green 2 GND black 3 K...

Страница 25: ...www mechatronics by Page 25 30 It is recommended to contact Mechatronics technical support or the nearest service center all contact you can find on our web site http www mechatronics by Fig 12 Simple...

Страница 26: ...EUROSENS Fuel flow meters Operation manual ver 1 6 www mechatronics by Page 26 30 Fig 13 Simple diagnostics of the Eurosens Direct P PH PN flow meters continuation...

Страница 27: ...EUROSENS Fuel flow meters Operation manual ver 1 6 www mechatronics by Page 27 30 Fig 14 Simple diagnostics of the Eurosens Delta PN flow meters...

Страница 28: ...0 C and relative humidity up to 100 at 25 C Do not store Eurosens flow sensors in the same room with substances that cause corrosion of the metal and or contain active agents Storage life of eurosens...

Страница 29: ...eters does not contain harmful substances and ingredients that are dangerous to human health and environment during and after the end of life and recycling Eurosens fuel flow meters do not contain pre...

Страница 30: ...EUROSENS Fuel flow meters Operation manual ver 1 6 www mechatronics by Page 30 30 Fig 17 Dimensions of the EUROSENS Delta PN RS CAN F Forward supply flow R Return return flow...

Отзывы: