IMPORTANT SAFETY INSTRUCTIONS 

 
Before using this generator and if you have any questions regarding the hazard and safety notices listed in this manual and/or on this generator, call 1-800-
832-2966, Monday - Friday, 9 AM - 6 PM Central Time. 

 

 

 

Carbon Monoxide Gas:

 When in operation, the exhaust from this generator contains poisonous carbon monoxide gas.  Carbon monoxide gas is both odorless 

and colorless and may be present even if you do not see or smell gas.  Breathing this poison gas can lead to headaches, dizziness, drowsiness, loss of 
consciousness and eventually death. 

Use this generator ONLY outdoors in non-confined areas. 
Keep at least several feet of clearance on all sides to allow for proper ventilation for this generator. 

 

Powerful Voltage: 

This generator produces powerful voltage, which can result in electrocution. 

Only electrical devices should be plugged into this generator, either directly or with an extension cord. NEVER connect a building electrical system to 
this generator without a qualified electrician completing the installation. 

Doing so voids your warranty. Such connections must isolate generator 

power from utility power and comply with local electrical laws and codes. Failure to comply can create a back feed into utili ty lines creating an 
electrocution hazard, which may result in serious injury or death. Such a back feed may cause this ge nerator to explode, burn, and create fires when 
utility power is restored. 

Do not use this generator in wet conditions (rain, snow, active sprinkler systems, wet hands, etc.). Always keep this generator dry and operate it with dry 
hands. 
Do not touch bare wires or outlets (receptacles). 
Do not allow children or non-qualified persons to operate this generator. 

 

 

High Temperatures:

 This generator produces heat when in operation.  Temperatures near the exhaust can exceed 150° Fahrenheit (65° Celsius). 

Do not touch hot surfaces.  Observe all warning placards on this generator denoting hot surfaces. 
Allow this generator to cool for several minutes after use before touching the engine, muffler, or other areas that are hot during operation and before storing or 
transporting the generator. 
Hot exhaust may ignite some materials.  Keep flammable materials away from this generator. 
Keep several feet of clearance on all sides of this generator during operation.  Do not enclose this generator in any structure. 

 

 

Usage: 

Avoid the use of extension cords if possible. If you choose to use them, be sure they are sized adequately to handle the flow of electricity. 

An undersized cord can overheat, short out and cause a fire. 

 

Usage: 

Consult a physician(s) before using this generator if using a pacemaker.  Electromagnetic fields in close proximity to a heart pacemaker 

could cause a pacemaker to malfunction or fail. Caution is necessary when near the engine, or when using the recoil star ter. 

 

Usage: 

Misuse of this generator can damage it or shorten its life. 

 

Use this generator only for its intended purpose. 

 

Operate this generator only on a dry, level surface. 

 

Allow this generator to run for several minutes before connecting any electrical devices. 

 

Promptly turn off any malfunctioning devices and disconnect them. 

 

Do not operate an excessive number of electrical devices in excess of the wattage capacity of this generator.  

 

Do not turn on electrical devices until 

after they are connected to this generator. 

 

Turn off all connected electrical devices before stopping this generator. 

 

 

Usage: 

Prolonged exposure to high noise levels can be hazardous to hearing.  Always wear ANSI-approved hearing protection when operating or 

working around the generator when it is running. 

 

Содержание MM2000DFI

Страница 1: ...uation that may occur We reserve the right to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN THIS GENERATOR TO THE RETAILER If you experience a problem have questions or need parts for this product please call Customer Service at 1 800 832 2966 Monday Friday 9 AM 6 PM Central Time A copy...

Страница 2: ... smell the generator exhaust you are breathing CO But even if you cannot smell the exhaust you could be breathing CO CALIFORNIA PROPOSITION 65 WARNING This product or the exhaust from this product may contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm For more information view OEHHA s Proposition 65 page https www p65warnings ca gov ...

Страница 3: ...t Outlets Clean Sine Wave Power Output safe for Sensitive Electronics Model MM2000DFI This unit is a Dual Fuel Gasoline or Propane LPG powered Inverter generator FEATURES 2000 Surge 1600 Running Watts Output 120VAC Operation 3 0 HP Engine 4 Stroke 4650 RPM Displacement CC 79 7 Low Oil Shut Off UL Listed Electrical Components Engine Shut Off Switch Spark Plug Model Torch A7RTC or NGK CR7HSA 1 Gallo...

Страница 4: ...Outlet 4 120V Outlets 1 120V RV Outlet Parallel Port Outlets Clean Sine Wave Power Output safe for Sensitive Electronics For all MECH MARVELS Generators in this Manual Recommended Fuel types Unleaded Gasoline Only with Octane rating of 87 or higher and no more than 10 Ethanol content Liquid Propane Gas commonly referred to as LP LPG and Propane High Altitude Use This generator is not recommended f...

Страница 5: ...NERATOR 16 STARTING THE GENERATOR USING PROPANE 16 Switching from Gasoline to Propane 16 Switching from Propane to Gasoline 16 Subsequent Use of this Generator 17 USING THE GENERATOR 18 ECONOMY SMART THROTTLE SWITCH 20 AC PARALLEL TERMINALS 20 Turning Off Generators while in Parallel Function 21 DC USAGE 21 STOPPING THE GENERATOR 21 MAINTENANCE CARE 22 Recommended Maintenance Schedule 22 22 Cleani...

Страница 6: ...dous situation which if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if no...

Страница 7: ...ons to operate this generator High Temperatures This generator produces heat when in operation Temperatures near the exhaust can exceed 150 Fahrenheit 65 Celsius Do not touch hot surfaces Observe all warning placards on this generator denoting hot surfaces Allow this generator to cool for several minutes after use before touching the engine muffler or other areas that are hot during operation and ...

Страница 8: ...al devices such as lights appliances or cell phones sparks from these sources can trigger an explosion or fire It can collect in low areas or travel along the ground where an ignition source may be present Pressure can also build up in the container due to heat and the container can rupture if the relief devices should fail to function Carbon Monoxide CO Carbon monoxide is a byproduct of combustio...

Страница 9: ...NEED HELP 1 800 832 2966 9 In addition to the previously described safety information familiarize yourself with all safety and hazard notices on this generator ...

Страница 10: ...66 Monday Friday 9 AM 6 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List Set of 2 DC connector wires for charging 12 Volt automotive type batteries Spark plug wrench Funnel for adding Oil T Handle Driver MM2000I DFI Sockets MM2000I DFI Phillips screwdriver MM2000I DFI 5 Ft Regulator Hose Kit Dual Fuel Units only YOU MUST USE THE SUPPLIED REGULATOR FOR SAF...

Страница 11: ...ocations and functions of the various components and controls of this generator 1 Handle 7 Removable Service Panel 2 Fuel Cap 8 Muffler 3 Fuel Valve 9 Oil Check Access 4 Recoil Starter 10 Fuel Drain Pipe 5 Control Panel 11 Wheel 6 Spark Plug Cover 1 11 6 9 8 5 4 2 ...

Страница 12: ...NEED HELP 1 800 832 2966 12 Control Panel Detail MM3000ISE Panel Shown ...

Страница 13: ...generator contains no oil in the engine crankcase Add the correct quantity of oil before operating this generator for the first time When replenishing oil for subsequent use of this generator always ensure that this generator has the correct quantity of oil Model MM2000I DFI Oil Capacity 13 5 ounces Model MM3000ISE Oil Capacity 18 6 ounces Oil Type Recommended for All Models High Detergent Motor O...

Страница 14: ...RCE Step 3 Ground the Generator Ground this generator by tightening the grounding nut against a grounding wire as illustrated in Figure 3 Number 6 AWG American Wire Gauge stranded copper wire is generally an acceptable grounding wire The other end of this grounding wire should be connected to a copper or brass grounding rod that is driven into the earth Grounding codes can vary by location Contact...

Страница 15: ... CHOKE VALVE is at CHOKE CLOSED position The generator may be hard to start if CHOKE VALVE is at the RUN OPEN position Step 3 Ensure engine oil is full Step 4 Make sure GROUND TERMINAL is properly grounded Step 5 Check AC OUTPUTS and ensure no load is connected Disconnect all electrical loads from the generator set before starting the engine The generator may be hard to start if a load is connecte...

Страница 16: ...ot connect any electrical devices to the generator prior to starting the engine 1 Make sure the fuel valve is in the OFF position 2 Make certain the propane hose is properly connected to the generator 3 Connect the regulator to the LPG fuel supply and open the LPG supply valve ENSURE THERE ARE NO LEAKS 4 Leave the unit un choked unless temperatures are below freezing 5 Turn the engine power switch...

Страница 17: ...he oil off of the dipstick that is located on the inside of the cap 4 Fully insert the dipstick without screwing the filler dipstick cap and then remove again There should be oil on the dipstick If there is no oil on the g Add 5 Confirm that the oil filler dipstick cap is properly screwed in place when finished verifying the oil level Step 3 Ground the Generator Ground this generator by tightening...

Страница 18: ...If the total wattage of the selected de vices exceeds the rated wattage of the generator DO NOT connect all of the devices Select a combination of the electrical devices that will have a total wattage less than or equal to the rated wattage for the generator SOME NOTES ABOUT POWER CORDS Long or thin cords can require more wattage from a generator to power an electrical device Figure 7 shows the re...

Страница 19: ... 1500 0 sump pump 800 1200 television 27 inch color 500 0 electric water heater 40 gallon 4000 0 window air conditioner 10000 BTU 1200 1800 window fan 300 600 Figure 8 Estimated wattage requirements for common electrical devices Connect electrical devices to this generator according to the following procedure 1 Allow the engine to run for several minutes after it has been started 2 Confirm that th...

Страница 20: ...r the left or right ports NOTE Do not connect disconnect cables while the generator is running The generator or the load may be damaged NOTE Only connect two identical Inverter Generators together using a Parallel Kit Before connecting an appliance to a generator make sure that the appliance is in good working order and that its electrical rating does not exceed that of the outlet Most appliances ...

Страница 21: ...he 12V DC outlet on this generator 3 Start this generator 4 When disconnecting turn of the generator and always disconnect the wires from this generator first to avoid the risk of a short circuit and spark STOPPING THE GENERATOR To stop this generator 1 Turn off all connected electrical devices and then unplug them 2 Allow this generator to run for several more minutes with no electrical devices c...

Страница 22: ...ecommended Maintenance Schedule Each Use Every Month or Each 20 Hrs Every 3 Months or Each 50 Hrs Every 6 Months or Each 100 Hrs Every Year or Each 300 Hrs Engine Oil Check Level X Change X First Use X Air Filter Check X Clean X Fuel Filter Clean X Spark Plug Check Clean X Spark Arrestor Clean X Valve Clearance Check Adjust X Fuel Lines Check Replace Check and Replace as needed every 2 years Clean...

Страница 23: ...the cover screw securely 6 Engine oil capacity 13 5 ounces 7 Wash your hands with soap and water after handling used oil NOTE Never dispose of used motor oil in the trash down a drain or on the ground Put oil in a sealed container and contact your local recycling center or auto garage to arrange oil disposal To add oil to the engine crankcase 1 Confirm that this generator is on a level surface 2 U...

Страница 24: ...NEED HELP 1 800 832 2966 24 Recommended plug NGK CR7HSA 0 60 0 80mm 0 024 0 031in Fig 15A Fig 15B Fig 15C Fig 15D ...

Страница 25: ...s cracked or chipped Clean the spark plug with a wire brush if it is to be reused 6 Measure the plug gap with a feeler gauge The gap should be 0 78 0 94mm 0 031 0 037 Correct as necessary by carefully bending the side electrode Fig 15C 7 Install the spark plug carefully by hand to avoid cross threading 8 After a new spark plug has been seated by hand it should be tightened 1 2 turn with a wrench t...

Страница 26: ...gasoline into a suitable container by the fuel drain pipe c When all the fuel is drained tum the petcock to the OFF position and tighten the drain screw securely 3 Change the engine oil 4 Remove the spark plug and pour about a table spoon of clean engine oil into the cylinder Crank the engine several revolutions to distribute the oil the reinstall the spark plug 5 Reinstall the spark plug cap on t...

Страница 27: ... 27 TROUBLESHOOTING 8 32 Be sure that there is no fuel spilled around the spark plug spilled fuel may ignite Does not spark Consult authorized service center Consult authorized service center See specifications in Maintenance ...

Страница 28: ...C 8A 1 120VAC RV 1 5VDC USB 1 5VDC USB 1 12VDC 12A 1 5VDC USB Net Gross Weight 46 7 50 7lbs 47 2 52 7lbs 133 4 142 0lbs Noise Level 53dB 53dB 65dB Fuel Types Gasoline Gasoline Gasoline LPG 20lb cylinder Fuel Capacity 1gal 1gal 3 35gal Fuel Gauge Yes Yes Yes Oil Type SAE 10W 30 SAE 10W 30 SAE 10W 30 Oil Capacity 13 5 ounces 13 5 ounces 18 6 ounces Starter Type Recoil Recoil Recoil Electric AC Volt ...

Страница 29: ...ny part that is proven to be defective in materials or workmanship under normal use during the 1 YEAR warranty period Warranty repairs or replacements will be made without charge for parts or labor Parts replaced during warranty repairs will be considered as part of the original product and will have the same warranty period as the original product This warranty gives you specific legal rights and...

Страница 30: ...ove Any such part repaired or replaced under warranty will be warranted for the remaining warranty period 3 Any warranted part that is scheduled for replacement as required maintenance in your owner s manual is warranted for the period of time before the first scheduled replacement date for that part If the part fails before the first scheduled replacement the part will be repaired or replaced by ...

Страница 31: ...pipe manifold b Air cleaner 3 Ignition system including a Spark plug b Ignition coil 4 Catalytic muffler assembly including a Muffler gasket b Exhaust manifold c Catalytic converter if available 5 Crankcase breather assembly including a Breather connection tube 6 Fuel tank evaporative emissions control system including a Purge valves b Carbon canister c Canister mounting brackets d Fuel cap e Fuel...

Отзывы: