Mech Marvels MM2000DFI Скачать руководство пользователя страница 30

NEED HELP:1-800-832-2966

 

30 

 

As the power equipment engine owner, you should however be aware that QJ NORTH AMERICA INC. may deny 

your  warranty  coverage  if  your  power  equipment  engine  or  a  part  has  failed  due  to  abuse,  neglect,  improper 

maintenance or unapproved modifications. 

You are responsible for presenting your power equipment engine to distribution center or service center 

authorized by QJ NORTH AMERICA INC. as soon as the problem exists. The warranty repairs should be 

completed in a reasonable amount of time, not to exceed 30 day. 
If you have any questions regarding your warranty rights and responsibilities, you should contact QJ NORTH 
AMERICA INC. customer service representative at 1-800-832-2966 or write to 

[email protected].

 

DEFECTS WARRANTY COVERAGE 

Adopted by the Air Resources Board, QJ NORTH AMERICA INC. warrants to the ultimate purchaser and each 

subsequent purchaser that the small off-road engine (SORE)(1) has been designed, built and equipped so as to 

conform with all applicable regulations; and (2) is free from defects in materials and workmanship that cause the 

failure of a warranted part to conform with those regulations as may be applicable to the terms and conditions 

stated below. 

(a) The warranty period begins on the date the engine is delivered to an ultimate purchaser or first placed into 

service. The warranty period is two years. 

(b) Subject to certain conditions and exclusions as stated below, the warranty on emissions related parts is as 

follows: 
Any warranted part that is not scheduled for replacement as required maintenance in your Owner’s Manual is 
warranted for the warranty period stated above. If the part fails during the period of warranty coverage, the part: 

(1) 

will be repaired or replaced by QJ NORTH AMERICA INC. According to Subsection (4)  below. Any such part 

repaired or replaced under warranty will be warranted for the remainder of the periods.

 

(2) 

Any warranted part that is scheduled only for regular inspection in your owner’s manual is warranted for the 

warranty period stated above. Any such part repaired or replaced under warranty will be warranted for the remaining 

warranty period.

 

(3) 

Any  warranted  part  that  is  scheduled  for  replacement  as  required  maintenance  in  your  owner’s  manual  is 

warranted for the period of time before the first scheduled replacement date for that part. If the part fails before the 

first  scheduled  replacement,  the  part  will  be  repaired  or  replaced  by  QJ  NORTH  AMERICA  INC.  According  to 

Subsection (4) below. Any such part repaired or replaced under warranty will be warranted for the remainder of the 

period prior to the first scheduled replacement point for the part.

 

(4) 

Repair  or  replacement  of  any  warranted  part  under  the  warranty  provisions  herein  must  be  performed  at  a 

warranty station at no charge to the owner.

 

(5) 

Notwithstanding  the  provisions  herein,  warranty  services  or  repair  will  be  provided  at  all  of  our  distribution 

centers that are franchised to service the subject engines.

 

(6) 

The engine owner must not be charged for diagnostic labor that leads to the determination that a warranted part 

is in fact defective, provided that such diagnostic work is performed at a warranty station.

 

(7) 

QJ NORTH AMERICA INC. is liable for damages to other engine components proximately caused by a failure 

under warranty of any warranted part.

 

(8) 

Throughout  the  engine  warranty  period  stated  above,  QJ  NORTH  AMERICA  INC.  will  maintain  a  supply  of 

warranted part sufficient to meet the expected demand for such parts.

 

(9) 

Any replacement may be used in the performance of any warranty maintenance or repairs and must be provided 

without charge to the owner. Such use will not reduce the warranty obligations of QJ NORTH AMERICA INC.

 

(10) 

Add-on or modified parts that are not exempted by the Air Resources Board may not be used. The use 

of any non-exempted add-on or modified parts by the ultimate purchaser will be grounds for disallowing a warranty 

claims. QJ NORTH AMERICA INC. will not be liable to warrant failures of warranted parts caused by the use of a 

non-exempted add-on or modified part.

 

(11) 

The manufacturer issuing the warranty shall provide any documents that describe that manufacturer’s 

warranty procedures or policies within five working days of request by the Air Resources Board.

 

Содержание MM2000DFI

Страница 1: ...uation that may occur We reserve the right to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN THIS GENERATOR TO THE RETAILER If you experience a problem have questions or need parts for this product please call Customer Service at 1 800 832 2966 Monday Friday 9 AM 6 PM Central Time A copy...

Страница 2: ... smell the generator exhaust you are breathing CO But even if you cannot smell the exhaust you could be breathing CO CALIFORNIA PROPOSITION 65 WARNING This product or the exhaust from this product may contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm For more information view OEHHA s Proposition 65 page https www p65warnings ca gov ...

Страница 3: ...t Outlets Clean Sine Wave Power Output safe for Sensitive Electronics Model MM2000DFI This unit is a Dual Fuel Gasoline or Propane LPG powered Inverter generator FEATURES 2000 Surge 1600 Running Watts Output 120VAC Operation 3 0 HP Engine 4 Stroke 4650 RPM Displacement CC 79 7 Low Oil Shut Off UL Listed Electrical Components Engine Shut Off Switch Spark Plug Model Torch A7RTC or NGK CR7HSA 1 Gallo...

Страница 4: ...Outlet 4 120V Outlets 1 120V RV Outlet Parallel Port Outlets Clean Sine Wave Power Output safe for Sensitive Electronics For all MECH MARVELS Generators in this Manual Recommended Fuel types Unleaded Gasoline Only with Octane rating of 87 or higher and no more than 10 Ethanol content Liquid Propane Gas commonly referred to as LP LPG and Propane High Altitude Use This generator is not recommended f...

Страница 5: ...NERATOR 16 STARTING THE GENERATOR USING PROPANE 16 Switching from Gasoline to Propane 16 Switching from Propane to Gasoline 16 Subsequent Use of this Generator 17 USING THE GENERATOR 18 ECONOMY SMART THROTTLE SWITCH 20 AC PARALLEL TERMINALS 20 Turning Off Generators while in Parallel Function 21 DC USAGE 21 STOPPING THE GENERATOR 21 MAINTENANCE CARE 22 Recommended Maintenance Schedule 22 22 Cleani...

Страница 6: ...dous situation which if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if no...

Страница 7: ...ons to operate this generator High Temperatures This generator produces heat when in operation Temperatures near the exhaust can exceed 150 Fahrenheit 65 Celsius Do not touch hot surfaces Observe all warning placards on this generator denoting hot surfaces Allow this generator to cool for several minutes after use before touching the engine muffler or other areas that are hot during operation and ...

Страница 8: ...al devices such as lights appliances or cell phones sparks from these sources can trigger an explosion or fire It can collect in low areas or travel along the ground where an ignition source may be present Pressure can also build up in the container due to heat and the container can rupture if the relief devices should fail to function Carbon Monoxide CO Carbon monoxide is a byproduct of combustio...

Страница 9: ...NEED HELP 1 800 832 2966 9 In addition to the previously described safety information familiarize yourself with all safety and hazard notices on this generator ...

Страница 10: ...66 Monday Friday 9 AM 6 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List Set of 2 DC connector wires for charging 12 Volt automotive type batteries Spark plug wrench Funnel for adding Oil T Handle Driver MM2000I DFI Sockets MM2000I DFI Phillips screwdriver MM2000I DFI 5 Ft Regulator Hose Kit Dual Fuel Units only YOU MUST USE THE SUPPLIED REGULATOR FOR SAF...

Страница 11: ...ocations and functions of the various components and controls of this generator 1 Handle 7 Removable Service Panel 2 Fuel Cap 8 Muffler 3 Fuel Valve 9 Oil Check Access 4 Recoil Starter 10 Fuel Drain Pipe 5 Control Panel 11 Wheel 6 Spark Plug Cover 1 11 6 9 8 5 4 2 ...

Страница 12: ...NEED HELP 1 800 832 2966 12 Control Panel Detail MM3000ISE Panel Shown ...

Страница 13: ...generator contains no oil in the engine crankcase Add the correct quantity of oil before operating this generator for the first time When replenishing oil for subsequent use of this generator always ensure that this generator has the correct quantity of oil Model MM2000I DFI Oil Capacity 13 5 ounces Model MM3000ISE Oil Capacity 18 6 ounces Oil Type Recommended for All Models High Detergent Motor O...

Страница 14: ...RCE Step 3 Ground the Generator Ground this generator by tightening the grounding nut against a grounding wire as illustrated in Figure 3 Number 6 AWG American Wire Gauge stranded copper wire is generally an acceptable grounding wire The other end of this grounding wire should be connected to a copper or brass grounding rod that is driven into the earth Grounding codes can vary by location Contact...

Страница 15: ... CHOKE VALVE is at CHOKE CLOSED position The generator may be hard to start if CHOKE VALVE is at the RUN OPEN position Step 3 Ensure engine oil is full Step 4 Make sure GROUND TERMINAL is properly grounded Step 5 Check AC OUTPUTS and ensure no load is connected Disconnect all electrical loads from the generator set before starting the engine The generator may be hard to start if a load is connecte...

Страница 16: ...ot connect any electrical devices to the generator prior to starting the engine 1 Make sure the fuel valve is in the OFF position 2 Make certain the propane hose is properly connected to the generator 3 Connect the regulator to the LPG fuel supply and open the LPG supply valve ENSURE THERE ARE NO LEAKS 4 Leave the unit un choked unless temperatures are below freezing 5 Turn the engine power switch...

Страница 17: ...he oil off of the dipstick that is located on the inside of the cap 4 Fully insert the dipstick without screwing the filler dipstick cap and then remove again There should be oil on the dipstick If there is no oil on the g Add 5 Confirm that the oil filler dipstick cap is properly screwed in place when finished verifying the oil level Step 3 Ground the Generator Ground this generator by tightening...

Страница 18: ...If the total wattage of the selected de vices exceeds the rated wattage of the generator DO NOT connect all of the devices Select a combination of the electrical devices that will have a total wattage less than or equal to the rated wattage for the generator SOME NOTES ABOUT POWER CORDS Long or thin cords can require more wattage from a generator to power an electrical device Figure 7 shows the re...

Страница 19: ... 1500 0 sump pump 800 1200 television 27 inch color 500 0 electric water heater 40 gallon 4000 0 window air conditioner 10000 BTU 1200 1800 window fan 300 600 Figure 8 Estimated wattage requirements for common electrical devices Connect electrical devices to this generator according to the following procedure 1 Allow the engine to run for several minutes after it has been started 2 Confirm that th...

Страница 20: ...r the left or right ports NOTE Do not connect disconnect cables while the generator is running The generator or the load may be damaged NOTE Only connect two identical Inverter Generators together using a Parallel Kit Before connecting an appliance to a generator make sure that the appliance is in good working order and that its electrical rating does not exceed that of the outlet Most appliances ...

Страница 21: ...he 12V DC outlet on this generator 3 Start this generator 4 When disconnecting turn of the generator and always disconnect the wires from this generator first to avoid the risk of a short circuit and spark STOPPING THE GENERATOR To stop this generator 1 Turn off all connected electrical devices and then unplug them 2 Allow this generator to run for several more minutes with no electrical devices c...

Страница 22: ...ecommended Maintenance Schedule Each Use Every Month or Each 20 Hrs Every 3 Months or Each 50 Hrs Every 6 Months or Each 100 Hrs Every Year or Each 300 Hrs Engine Oil Check Level X Change X First Use X Air Filter Check X Clean X Fuel Filter Clean X Spark Plug Check Clean X Spark Arrestor Clean X Valve Clearance Check Adjust X Fuel Lines Check Replace Check and Replace as needed every 2 years Clean...

Страница 23: ...the cover screw securely 6 Engine oil capacity 13 5 ounces 7 Wash your hands with soap and water after handling used oil NOTE Never dispose of used motor oil in the trash down a drain or on the ground Put oil in a sealed container and contact your local recycling center or auto garage to arrange oil disposal To add oil to the engine crankcase 1 Confirm that this generator is on a level surface 2 U...

Страница 24: ...NEED HELP 1 800 832 2966 24 Recommended plug NGK CR7HSA 0 60 0 80mm 0 024 0 031in Fig 15A Fig 15B Fig 15C Fig 15D ...

Страница 25: ...s cracked or chipped Clean the spark plug with a wire brush if it is to be reused 6 Measure the plug gap with a feeler gauge The gap should be 0 78 0 94mm 0 031 0 037 Correct as necessary by carefully bending the side electrode Fig 15C 7 Install the spark plug carefully by hand to avoid cross threading 8 After a new spark plug has been seated by hand it should be tightened 1 2 turn with a wrench t...

Страница 26: ...gasoline into a suitable container by the fuel drain pipe c When all the fuel is drained tum the petcock to the OFF position and tighten the drain screw securely 3 Change the engine oil 4 Remove the spark plug and pour about a table spoon of clean engine oil into the cylinder Crank the engine several revolutions to distribute the oil the reinstall the spark plug 5 Reinstall the spark plug cap on t...

Страница 27: ... 27 TROUBLESHOOTING 8 32 Be sure that there is no fuel spilled around the spark plug spilled fuel may ignite Does not spark Consult authorized service center Consult authorized service center See specifications in Maintenance ...

Страница 28: ...C 8A 1 120VAC RV 1 5VDC USB 1 5VDC USB 1 12VDC 12A 1 5VDC USB Net Gross Weight 46 7 50 7lbs 47 2 52 7lbs 133 4 142 0lbs Noise Level 53dB 53dB 65dB Fuel Types Gasoline Gasoline Gasoline LPG 20lb cylinder Fuel Capacity 1gal 1gal 3 35gal Fuel Gauge Yes Yes Yes Oil Type SAE 10W 30 SAE 10W 30 SAE 10W 30 Oil Capacity 13 5 ounces 13 5 ounces 18 6 ounces Starter Type Recoil Recoil Recoil Electric AC Volt ...

Страница 29: ...ny part that is proven to be defective in materials or workmanship under normal use during the 1 YEAR warranty period Warranty repairs or replacements will be made without charge for parts or labor Parts replaced during warranty repairs will be considered as part of the original product and will have the same warranty period as the original product This warranty gives you specific legal rights and...

Страница 30: ...ove Any such part repaired or replaced under warranty will be warranted for the remaining warranty period 3 Any warranted part that is scheduled for replacement as required maintenance in your owner s manual is warranted for the period of time before the first scheduled replacement date for that part If the part fails before the first scheduled replacement the part will be repaired or replaced by ...

Страница 31: ...pipe manifold b Air cleaner 3 Ignition system including a Spark plug b Ignition coil 4 Catalytic muffler assembly including a Muffler gasket b Exhaust manifold c Catalytic converter if available 5 Crankcase breather assembly including a Breather connection tube 6 Fuel tank evaporative emissions control system including a Purge valves b Carbon canister c Canister mounting brackets d Fuel cap e Fuel...

Отзывы: