93808 – October 2014
Page 21
6092RT
Operating Instructions
Outrigger Operation
Only lower the outriggers when the machine is on a firm surface. The surface must be capable
of supporting the maximum ground pressure per wheel/outrigger (see specifications).
The outrigger control switches is located on the front face of the Upper Control Box.
Extend
Push down and hold the Automatic Leveling Switch to the EXTEND position.
• The outriggers will extend and level the machine. When the machine is level
and ready to operate, the outriggers will stop automatically.
• The Drive Enable Indicator will turn OFF, indicating that outriggers are down
and machine drive function is disabled.
Retract
Push up and hold the Outrigger Control Switch to the RETRACT position.
• The outriggers will retract.
• The Drive Enable Indicator will turn ON, indicating that the outriggers are up
and machine drive function is enabled.
Manual Operation Of Outriggers
Manual operation of individual outriggers is possible using the Manual Level Switches.
Shutdown Procedure
• When finished with the machine, place the platform in the stowed position.
• Park the machine on a level surface.
• Turn the Selector Key Switch to the OFF position and remove the key to prevent
unauthorized use.
• Carefully exit the platform using a constant three (3) point dismount/grip.
ART_3031 R1
91844
Automatic
Leveling
Manual Level
Switches
Drive Enable
Indicator
ART_3032
ART_3037