Measurement Technology NW
LCI-90 Operator Manual
Page 67
15.0 Appendix G – LCI-90R Specifications
LCI-90R
PHYSICAL/POWER
Std/Option
Temp.
-40
˚
C to 75
˚
C
Std
Environmental
NEMA 4X front panel
Std
NEMA 1 rear enclosure
Std
Dimensions
7.6” wide x 5.7” high x 4.0” deep
Std
Cut out: 7.15” wide x 5.25 high
Std
Weight
3.4 pounds
Std
Materials
Stainless Steel 315 front panel
Std
Polycarbonate display window
Std
Urethane front panel gasket
Std
Power
18-36 VDC, 0.5 A typical, 0.75 A maximum
Std
85-250 VAC, 13 W typical, 18 W maximum
AC
Heat Output
8 Watts typical
Std
LCI-90R
DISPLAY
Std/Option
Type
Graphic electro-luminescent, 320 x 240 pixels
Std
View Angle
160 degrees
Std
Viewing Area
4.7” wide x 3.6” high
Std
Brightness
High brightness – 50 cd/m2
Std
Ultra high brightness – 340 cd/m2
HT
Contrast
Fixed
Std
Adjustable
HT
Characters
8 at top center, 4 at lower left, 5 at lower right
Std
LCI-90R
SERIAL COMMUNICATION
Std/Option
Type
Network Port, RS-232, non-isolated
Std
Network Port, RS-485, 2 wire, isolated
11
Auxiliary Port, RS-232, non-isolated
12
Baud Rate
4800 to 19200
Std
Protection
RS-485 option, 2500 V rms
11