Direct Input – 4-20 mA, Two Wire, Channel 1
TB1
Force Xducer: 2 Wire, 4-20 mA
+ 24 VDC
EXCITATION
TB1
1+
Note: Jumper H1 must be inserted.
Figure 4.6 – Tension Hookup – 2 Wire 4-20 mA Signal
Direct Input – DC Voltage, +24 Volt Excitation, Channel 1
TB5
Force Xducer: Voltage Output
+24 VDC
EXCI
GND
EXCITATION –
TB1
1+
1–
SIGNAL –
Figure 4.7 – Tension Hookup – 4 Wire DC Voltage Input
Isolated Input – 4 Wire Strain Gauge with Module
TB6
Force Xducer: Strain Gauge
MOD1 - V+
EXCI
MOD1 - V–
EXCITATION –
TB6
MOD1 - S+
MOD1 - S–
SIGNAL –
Note: 4 wire strain gauge module must be inserted in correct position.