
MSI-9300 Crane Scale™
•
User Guide Page 11
MEASUREMENT SYSTEMS INTERNATIONAL
Rev 1 7/27/02 for SW Ver 1-1
TEST
Provides a functional system test, and an on-demand display check without disturbing the current weighment.
The Test function can be interrupted by pushing any key during the test.
To start the Test
1
TEST
8.8.8.8.8.8
2
b= 80.5
3
nt 17
4
id 17
5
000000
111111
999999
Push the TEST/USER key (programmed as TEST). The
display will do the following steps:
1) All LEDs are illuminated for 1 second.
2) The battery condition in approximate per cent of remain-
ing life is displayed.
3) The Network Address is displayed.
Numbered from 0-31
4) The Network ID is displayed.
Numbered from 0 to 254
5) The display digits count up from 0 to 9.
6) Returns to normal weight mode.
INTERNAL TEMPERATURE DISPLAY
The MSI-9300 can monitor its internal temperature. This feature is for use in Foundry applications or any other
Crane use around high temperature sources. The temperature display can be set to display automatically at 20
second intervals (see page 15) and will display in degrees C or degrees F. The purpose of monitoring the inter-
nal temperature is to ensure that the scale is not damaged by overlong exposure to high temperatures. The MSI-
9300 offers a heat shield option for foundry use that increases the dwell time possible when lifting melt pots.
MSI-9300 Series Crane Scales must be immediately removed from the high heat source when the inter-
nal temperature reaches 158°F or 70°C.
To Manually Display the MSI-9300 Internal Temperature
USER key Function set to “ °F °C ”. Temperature units are set in the Setup Menus.
TEST
71.2°C
Push the TEST/USER key. The current internal tempera-
ture will display for 2 seconds.
RF LIST
When the scale is used in multiple RF Networks, the RF List function allows the user to easily switch between
several networks. These networks must be setup in the embedded CellScale (See MSI-9000 User Guide).t
This operation requires that the Test/User Key function is set to RFList. See “Setup USER key Function ”.