PCI-DAS6030 & PCI-DAS6032 User's Guide
Functional Details
24
Trigger Below
The acquisition will begin when ATRIG signal fist goes below the THRESH_LO level. This mode is non-
retriggerable.
Figure 20. Trigger Negative Slope
Gate Above
Data acquisition is enabled whenever ATRIG goes above the THRESH_HI level. Acquisition is suspended
whenever the ATRIG signal goes below the THRESH_HI level. This is a level-sensitive gating mode.
Figure 21. Gate Above
Thresh_LO
+2
-2
+1
0
-1
Trigger
Acquired Data
+2
-2
+1
0
-1
Trigger
Result
+2
-2
+1
0
-1
Thresh_HI
+2
+1
0
-1
+2
-2
+1
0
-1