CIO-EXP16 User's Guide
Installing the CIO-EXP16
Information on signal connections
General information regarding signal connection and configuration is available in the
Guide to Signal
Connections
www.mccdaq.com/signals/signals.pdf
).
Configuring the CIO-EXP16
Before using the CIO-EXP16, there are switches and jumpers to set, and one or more cables to install. Please
turn the PC power OFF before proceeding. The CIO-EXP16 is shipped with the factory-default settings listed in
the following table.
Factory-configured default settings
Jumper/switch Description
Default
setting
Power source select switch
S3
+5V power switch that sets the power source to
internal or external
INT (in5V PC power)
A/D BOARD TYPE jumper
Selects DAS08 or DAS16 compatibility
DAS08
EXP OUTPUT TO DAS
jumper
Selects the A/D board channel to connect the
multiplexed analog output to.
0
(EXP multiplexed output connects to
channel 0 on the A/D board)
CJC OUTPUT TO DAS
jumper
Selects the A/D board channel to connect the
CJC output to.
7
(CJC circuit connects to channel 7 on
the A/D board)
GAIN switches
S1
Four DIP switches that set the gain of the
differential amplifier.
Gain = 1 (all gain switches OFF)
V, C and G solder bridge
switches (one for each input
channel)
Three 'connect pads' per channel on the etch
side (under side) of the CIO-EXP16 board.
Bridge each pad to configures its associated
input channel as follows:
Bridge the
V
pads to enable
open
thermocouple
detection
for the associated
input channel.
Bridge the
C
pads to connect a 1 µF
capacitor across the signal high and low
inputs, forming a low-pass filter having a 7
Hz cutoff.
Bridge the
G
pads to enable a
reference
to
ground
for the associated input channel.
Open pads (all are not bridged)
12