![Mean Well RPB-1600 Series Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/mean-well/rpb-1600-series/rpb-1600-series_instruction-manual_1757955012.webp)
10
Note:
EEPER
When EEPROM Charge Parameter Error occurs, the charger stops charging the battery and
:
the LED indicator turns red. The charger needs to re-power on to re-start charging the
battery.
NTCER
When Temperature Compensation Short occurs, the charger output will shut down and the
:
LED indicator will turn red. The charger will automatically restart after the Temperature
Compensation Short condition is removed.
BTNC
When there is no battery detected, the charger stops charging the battery and the LED
:
indicator turns red. The charger needs to re-power on to re-start charging the battery.
CCTOF
When timeout arises in the Constant Current stage, the charger stops charging the battery
:
and the LED indicator turns red. The charger needs to re-power on to re-start charging the
battery.
CVTOF
When timeout arises in the Constant Voltage stage, the charger stops charging the battery
:
and the LED indicator turns red. The charger needs to re-power on to re-start charging the
battery.
FVTOF
When timeout arises in the Float stage, the charger stops charging the battery and the LED
:
indicator turns green. This charging flow is finished; the charger needs to re-power on to
start charging a different battery.