12

24V

5A

3.2A

3.7A

OUTPUT
(MD-100)

DC VOLTAGE

OUTPUT VOLTAGE CODE

MD-100R

MD-100S

MD-100T

MD-100U

MD-100V

MD-100X

5V

5V

5V

15V

5V

12V

15V

24V

15V

10A

10A

10A

4A

8A

4.2A

3.4A

2.5A

2.7A

2 ~ 10A

2 ~ 10A

2 ~ 10A 0 ~ 4.7A

1 ~ 4.7A

0 ~ 8A

0 ~ 5.8A

0.5 ~ 3A

0 ~ 4.7A

90W

100.4W

101W

100W

100.5W

100mVp-p

150mVp-p

150mVp-p 200mVp-p

150mVp-p

100mVp-p

100mVp-p

100mVp-p

150mVp-p

4.75 ~ 5.5V 4.75 ~ 5.5V 4.75 ~ 5.5V

4.75 ~ 5.5V

14.2 ~ 16.5V 14.2 ~ 16.5V

11.4 ~ 13.2V

14.2 ~ 16.5V 22.8 ~ 26.4V 4.75 ~ 5.5V

±

3.0%

±

3.0%

±

3.0%

±

3.0%

±

3.0%

±

3.0%

±

3.0%

±

3.0%

±

3.0%

±

2.0%

±

1.0%

±

1.0%

±

1.0%

±

1.0%

±

1.0%

±

1.0%

±

1.0%

±

1.0%

±

1.0%

±

0.5%

±

2.0%

±

2.0%

±

2.0%

±

2.0%

±

2.0%

±

2.0%

±

2.0%

±

2.0%

±

2.0%

±

1.0%

1500ms, 50ms, 20ms at full load

1 SLOT Isolated Dual output (100W)  MD-100

RATED CURRENT

CURRENT RANGE

RATED POWER

Note.6

RIPPLE & NOISE (max.)

Note.2

VOLTAGE ADJ. RANGE

VOLTAGE TOLERANCE

Note.3

LINE REGULATION

LOAD REGULATION

SETUP, RISE, HOLD UP TIME

105 ~ 150% rated output power

5V

8A

0 ~ 10A

100mVp-p

12V

3.4A

0 ~ 4.7A

100.8W

120mVp-p

11.4 ~ 13.2V

±

3.0%

±

2.0%

±

1.0%

±

0.5%

±

2.0%

±

1.0%

24V

2.5A

0.6 ~ 3A

240mVp-p

22.8 ~ 26.4V

12V

12V

5A

3.4A

1 ~ 5A 0 ~ 5.8A

100.8W

120mVp-p 120mVp-p

11.4~ 13.2V 11.4~ 13.2V

±

3.0%

±

2.0%

±

1.0%

±

0.5%

±

2.0%

±

1.0%

MD-100W

OVERLOAD

OVER VOLTAGE

PROTECTION

Protection type : Shut down o/p voltage, re-power on to recover

Protection type : Shut down o/p voltage, re-power on to recover

5.6 ~ 7.2V 5.6 ~ 7.2V 5.6 ~ 7.2V

5.6 ~ 7.2V

13.3 ~ 17V

16.6 ~ 22V

16.6 ~ 22V

16.6 ~ 22V

26.5 ~ 34V 5.6 ~ 7.2V

13.3 ~ 17V

26.5 ~ 34V

13.3 ~ 17V 13.3 ~ 17V

REMOTE INHIBIT CONTROL

RC+/RC-: 0 ~ 0.8V or OPEN, POWER ON          RC+/RC-: 4 ~ 12V POWER OFF

FUNCTION

±

0.5%

±

0.5%

±

0.3%

±

0.3%

±

0.2%

±

0.2%

±

1.0%

±

1.0%

±

0.5%

±

0.5%

±

0.5%

±

0.5%

1500ms, 50ms, 20ms at full load

LINE REGULATION

LOAD REGULATION

SETUP, RISE, HOLD UP TIME

OVERLOAD

OVER VOLTAGE

PROTECTION

116 ~ 150% rated output power

Protection type : Shut down o/p voltage, re-power on to recover

4.1 ~ 5V

6.1 ~ 7.5V

13.3 ~ 18V

16.9 ~ 22V

26.5 ~ 35V

53.1 ~ 60V

Protection type : Constant current limiting, recovers automatically after fault condition is removed

REMOTE INHIBIT CONTROL

RC+/RC-: 0 ~ 0.8V or OPEN, POWER ON          RC+/RC-: 4 ~ 12V POWER OFF

FUNCTION

OUTPUT
(MS-75)

DC VOLTAGE

OUTPUT VOLTAGE CODE

3.3V

5V

12V

15V

48V

15A

15A

6.3A

1.6A

0 ~ 15A

0 ~ 15A

0 ~ 6.3A

0 ~ 5A

0 ~ 3.2A

0 ~ 1.6A

17.3A

17.3A

7.3A

5.8A

1.8A

49.5W

75W

75.6W

75W

76.8W

76.8W

80mVp-p

80mVp-p

150mVp-p

150mVp-p

150mVp-p

250mVp-p

2.6 ~ 4V

4 ~ 6V

9 ~ 13.2V

13.2 ~ 16.8V

20 ~ 26.4V

40 ~ 53V

±

2.0%

±

2.0%

±

1.0%

±

1.0%

±

1.0%

±

1.0%

MS-75L

MS-75M

MS-75N

MS-75O

MS-75P

MS-75Q

1 SLOT Single output (75W)  MS-75

RATED CURRENT

CURRENT RANGE

PEAK LOAD

Note.4

RATED POWER

RIPPLE & NOISE (max.)

Note.2

VOLTAGE ADJ. RANGE

VOLTAGE TOLERANCE

Note.3

NOTE

1. MP450:The value changed by installing different output modules. The efficiency in specification means output modules are composed by following modules.

                5V(Voltage code C)*1, 12V(Voltage code E)*1, 24V(Voltage code H)*1, 5V(Voltage code M)*1.

    MP650:The value changed by installing different output modules. The efficiency in specification means output modules are composed by following modules.

                5V(Voltage code C)*2, 12V(Voltage code E)*1, 24V(Voltage code H)*2.    

    MP1K0:The value changed by installing different output modules. The efficiency in specification means output modules are composed by following modules.

                5V(Voltage code C)*2, 12V(Voltage code E)*2, 24V(Voltage code H)*3.

    The hold-up time of above combination is 20ms(typ.)

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

4. 35% Duty cycle maximum within every 10 seconds. Average output power should not exceed the rated power.

5. 

 

The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on 

  a 

mm*

mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.

720

360

 For guidance on how to 

    perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)

6. If the output voltage adjust to higher level, the rated current should be derated to meet the total rated power for both outputs(For MD-100 only).

7.The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).

Содержание MP1K0

Страница 1: ...MP450 650 1K0 Instruction Manual...

Страница 2: ...4 2 Installation Method 4 3 Derating 6 1 Front End 5 1 Series Connection Accessory 6 2 Output Module 5 2 Parallel Connection Accessory 3 3 Output Voltage Adjustment Range 3 4 Short Circuit Protection...

Страница 3: ...lel code For MS 210 MS 300 MS 360 only Code Model MS 300 360 MS 210 X 1 2 3 4 5 6 7 8 9 SLOT1 SLOT2 SLOT3 SLOT4 SLOT5 SLOT6 SLOT7 Code X 1 2 7 8 9 for MP450 MP650 Code X 1 2 3 4 5 6 7 8 9 for MP1K0 Ma...

Страница 4: ...6 or equivalent Pin No 1 3 2 Assignment AC L FG AC N TB1 PFC 450 650 1K0 2 MP450 MP650 MP1K0 4 M4 19 16 max 12 5 38 63 5 147 5 254 19 101 5 127 12 25 147 5 8 M4 Both Sides 12 max 10 8 2 TB1 3 2 1 Air...

Страница 5: ...e difference among each output should be minimized that less than 2 is required 2 The total output current must not exceed the value determined by the following equation Output current at parallel ope...

Страница 6: ...n 2 is required 2 The total output current must not exceed the value determined by the following equation Output current at parallel operation The rated current per unit Number of unit 0 9 Pin No Pin...

Страница 7: ...WELL for repair AC When using this function the sensing wires should either be twisted or shielded to prevent external noise interference refer to figure 3 1 Built in remote sense circuit in MS 75 MS...

Страница 8: ...he remote ON OFF control function Please refer to figure 3 2 for connecting methods 3 11 Remote ON OFF Control Output Modules Built in remote ON OFF control circuit for each output module All output m...

Страница 9: ...parallel and the maximum output current is 90A 50A 50A 0 9 Figure 3 8 Operating in series connection 3 14 Series Operation Higher output voltage can be acquired by using MS 75 MS 150 MS 210 MS 300 or...

Страница 10: ...wn in Figure 4 2 In order to maintain a safe isolation distance from internal components please use screws with length less than 6mm measured from the case as shown in Figure 4 3 Figure 4 1 System ass...

Страница 11: ...ut load derating is required for proper operation in high ambient temperature or at low AC input Please refer to the output derating curves of MP450 MP650 and MP1K0 shown in Figure 4 4 4 3 Derating Se...

Страница 12: ...12V POWER OFF FUNCTION PFC 450 PFC 650 PFC 1000 MODEL VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR EFFICIENCY Note 1 AC CURRENT INPUT INRUSH CURRENT LEAKAGE CURRENT 85 264VAC 120 370VDC 47 63Hz PF 0 95...

Страница 13: ...70W 100W 120W 165W 198W 115 5W 175W 250W 300W 210W 300W 360W 210W 300W 360W 210W 300W 360W 208 8W 300 6W 360W 210W 300W 360W 210 6W 302 4W 361 8W 211 2W 300 3W 363W 211 2W 302 4W 360W 50mVp p 80mVp p...

Страница 14: ...12V 15V 48V 15A 15A 6 3A 1 6A 0 15A 0 15A 0 6 3A 0 5A 0 3 2A 0 1 6A 17 3A 17 3A 7 3A 5 8A 1 8A 49 5W 75W 75 6W 75W 76 8W 76 8W 80mVp p 80mVp p 150mVp p 150mVp p 150mVp p 250mVp p 2 6 4V 4 6V 9 13 2V 1...

Отзывы: