9
AMBIENT TEMPERATURE (
)
℃
R
A
T
E
D P
O
W
E
R (
%
)
-20
0
10
20
30
40
50
20
40
50
60
80
100
Figure 4-4 Output derating curves for Modular Series
INPUT VOLTAGE (V) 60Hz
100
90
80
85
70
60
R
A
T
E
D P
O
W
E
R (
%
)
60
70 (HORIZONTAL)
85
90
100
120
140
160
180
200
220
240
264
◎
The Modular Series consists of PFC front-end and output modules. The electrical specification of each output module should be
carefully checked before operating and the total output power of all modules that is actually used should be less than the rated
power of its PFC front-end.
◎
Output load derating is required for proper operation in high ambient temperature or at low AC input. Please refer to the output derating
curves of MP450, MP650, and MP1K0 shown in Figure 4-4.
4.3
Derating
Series Connection Accessory
FAS 001
-
(
-
:
For 1 slot modules
- /
,
-
)
MS 75 150 MD 100
FAS 002
-
(
-
:
For 2 slot modules
-
)
MS 300
FAS 003
-
(
-
:
For 1 slot modules
-
)
MS 210
FAS 004
-
(
-
:
For 2 slot modules
-
)
MS 360
5.1 Series Connection Accessory
5.
Series Parallel Connection Accessory
/
Parallel Connection Accessory
FAP 001
-
(
)
For MS-300, 2 units
FAP 005
-
(
)
For MS-210, 4 units
FAP 002
-
(
)
For MS-300, 3 units
FAP 006
-
(
)
For MS-210, 5 units
FAP 003
-
(
)
For MS-210, 2 units
FAP 007
-
(
)
For MS-360, 2 units
FAP 004
-
(
)
For MS-210, 3 units
FAP 008
-
(
)
For MS-360, 3 units
5.2 Parallel Connection Accessory
Содержание MP1K0