41
Note:
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
High byte
-
-
-
-
-
-
-
-
-
-
Low byte
-
-
-
OPERATION_INIT
PM_CTRL
Low byte
Bit 0
PM_CTRL
PMBus Control Selection
Bit 1: 2 OPERATION_INIT :
OPERATION_INIT :
Initial Operational Behavior
0b00=
power on with 0x00: OFF
0b01=
power on with 0x80: ON(default)
0b10=
power on with the last setting
0b11=
Not used
Note:
Unsupported settings display with
"0"
0=
Output voltage and current controlled by SVR/PV/PC (default)
1=
Output voltage, current and remote ON/OFF controlled by PMBus
(VOUT_TRIM IOUT_FAULT_LIMIT OPERATION)
、
、
NTCER
:
When Temperature Compensation Short occurs, the output will
shut down and the LED indicator will turn red. The charger will
automatically restart after the Temperature Compensation
Short condition is removed.
BTNC
:
When there is no battery detected, the charger stops charging
the battery and the LED indicator turns red. The charger needs
to re-power on to re-start charging the battery.
CCTOF
:
When timeout arises in the Constant Current stage, the charger
stops charging the battery and the LED indicator turns red. The
charger needs to re-power on or remote on/off to re-start
charging the battery.
CVTOF
:
When timeout arises in the Constant Voltage stage, the charger
stops charging the battery and the LED indicator turns red. The
charger needs to re-power on or remote on/off to re-start
charging the battery.
FVTOF
:
When timeout arises in the Float stage, the charger stops
charging the battery and the LED indicator turns green. This
charging flow is finished; the charger needs to re-power on or
remote on/off to start charging a different battery.
◎
Definition of
Command BEh SYSTEM_CONFIG
:
6
42
Bit 4 ADL_ON :
Active dummy load Status
Bit 5 INITIAL_STATE :
Initial Stage Indication
Bit 6 EEPER:
EEPROM Access Error
0=
Active dummy load NOT activate
0=
The unit NOT in an initial state
0=
EEPROM accessing normally
1=
Active dummy load activate
1=
The unit in an initial state
1=
EEPROM access error
Note:
Unsupported settings display with "0".
Note:
1.EEPROM
:
When EEPROM Access Error occurs, the unit stops working
and the LED indicator turns red. The unit needs to re-power
on to recover after the error condition is removed
2.
Unsupported settings display with "0".
6.1.3 Notes on PMBus
1 Insert a at least 50msec delay between commands.
.
2.Examples for Format Conversion:
(1) LINEAR16 format: VOUT_COMMAND, VOUT_TRIM, READ_VOUT,
CURVE_CV and CURVE_FV.
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
High byte
-
-
-
EEPER
ADL_ON
INITIAL_
STATE
-
-
-
-
-
-
-
-
-
Low byte
DC_OK
Low byte
Bit 1: DC_OK :
The DC output Status
0=
DC output too low
1=
DC output at a normal range
◎
Definition of
:
Command BFh SYSTEM_STATUS
6
Linear Format Data Bytes
The Mode bits are set to 000b.
The Voltage, in volts, is calculated from the equation:
2
N
Voltage V
=
Where:
Voltageis the parameter of interest in volts;
V is a 16 bit unsigned binary integer; and
N is a 5 bit two' complement binary integer.
s