Installation
Manual
Type
:
General
Type
DIN
rail
with
Three
Phase
or
High
Input
Range
(
Series
:
DRH
‐
120,
DRT
‐
240,
DRT
‐
480,
DRT
‐
960
)
DRH
‐
120
‐
24
INPUT:
400
‐
500VAC
0.65A
50/60Hz
OUTPUT:
24V
5A
DRH
‐
120
‐
48
INPUT:
400
‐
500VAC
0.65A
50/60Hz
OUTPUT:
48V
2.5A
DRT
‐
240
‐
24
INPUT:
400
‐
500VAC
0.95A
50/60Hz
OUTPUT:
24V
10A
DRT
‐
240
‐
48
INPUT:
400
‐
500VAC
0.95A
50/60Hz
OUTPUT:
48V
5A
DRT
‐
480
‐
24
INPUT:
400
‐
500VAC
1.7A
50/60Hz
OUTPUT:
24V
20A
DRT
‐
480
‐
48
INPUT:
400
‐
500VAC
1.7A
50/60Hz
OUTPUT:
48V
10A
DRT
‐
960
‐
24
INPUT:
400
‐
500VAC
2.4A
50/60Hz
OUTPUT:
24V
40A
DRT
‐
960
‐
48
INPUT:
400
‐
500VAC
2.4A
50/60Hz
OUTPUT:
24V
20A
Introduction
General
type
with
three
phase
or
high
input
range
is
a
DIN
rail
power
supply
series
with
a
high
input
range,
340
‐
550Vac.
Like
other
Mean
Well’s
DIN
series,
they
can
be
mounted
on
a
TS35
Standard
DIN
rail.
Installation
(
1
)
Always
allow
good
ventilation
clearances,
5mm
left
and
right,
40mm
above
and
20mm
below,
around
the
unit
in
use
to
prevent
it
from
overheating.
Also
a
10
‐
15
cm
clearance
must
be
kept
when
the
adjacent
device
is
a
heat
source.
(
2
)
The
appropriate
mounting
orientation
for
the
unit
is
vertical,
the
input
terminals
at
the
bottom
and
output
on
the
top
for
DRH
‐
120,
the
input
terminals
on
the
right
and
output
on
the
left
for
DRT
‐
240,
DRT
‐
480
and
DRT
‐
960.
Mounting
orientations
other
than
that,
such
as
upside
down,
horizontal,
or
table
‐
top
mounting,
is
not
allowed.
(
3
)
Use
copper
wire
only,
and
recommended
wires
are
shown
as
below.
AWG
18
16
14
12
10
Rated
Current
of
Equipment
(Amp)
6A
6
‐
10A
13
‐
16A
16
‐
25A
25
‐
32A
Cross
‐
section
of
Lead(mm
2
)
0.75
1.00
1.5
2.5
4
Note:
Current
each
wire
carries
should
be
de
‐
rated
to
80%
of
the
current
suggested
above
when
using
5
or
more
wires
connected
to
the
unit.
Make
sure
that
all
strands
of
each
stranded
wire
enter
the
terminal
connection
and
the
screw
terminals
are
securely
fixed
to
prevent
poor
contact.
If
the
power
supply
possesses
multi
‐
output
terminals,
please
make
sure
each
contact
is
connected
to
wires
to
prevent
too
much
current
stress
on
a
single
contact.
(
4
)
Use
wires
that
can
withstand
temperatures
of
at
least
80°C
such
as
UL1007.
(
5
)
Recommended
wire
strapping
length
is
5mm
(0.197”).
(
6
)
Recommended
screwdriver
is
4mm,
slotted
type.
(
7
)
The
recommended
torque
setting
for
terminals
is
10
kgf
‐
cm
(9
Lb
‐
in).