background image

Icon

RC Reception Strength

Undefined data

Reception failed for 24 hours

Weak signal, but can be decoded

Strong signal

(Flashing)

Programming Time Alarms

• In the Clock and Alarm Mode, press the 

ALARM/CHART

 selecting the desired alarm.

• Press and hold 

ALARM/CHART

 button until the hour digit will flash

• Set the alarm hour using the 

UP

? or

DOWN

. Press and hold either button for quick digit advance.

• Press ALARM/CHART to confirm selection.
• Set the alarm minutes using 

UP

?  or 

DOWN

. Press and hold either button for quick digit advance.

• Press 

ALARM/CHART

 to confirm selection.

• Set a Snooze interval (all three alarms share same snooze time duration) using UP ?  or DOWN ? . Press and hold either 
  button for quick digit advance.
• Press 

ALARM/CHART

 to confirm your selection.

After programming is completed, the display will return to the alarm selection screen.

Note:

 Pre-alarm (Ice Warning Alarm) can be set only if the weekday alarm or single alarm is enabled.

Disabling or Enabling Snooze function

To enable a snooze function press 

LIGHT/SNOOZE

 button. Snooze duration is programmable and can set: from 1 to 

15 minutes.

Note:

 When the alarm sounds for 2 minutes the clock will automatically Snooze if no buttons are pressed. This will occur for 

three consecutive snooze cycles.

To disable alarm(s):

Press

ALARM/CHART

 to disable the alarm (s).

Note: For weekday alarm, pressing 

ALARM/CHART

 will only disable the alarm for the current day. The alarm will activate 

again on the next day, Monday through Friday.

Atomic Time Reception

The main unit synchronizes the time and date with WWVB radio clock broadcasts maintaining the atomic time precision.

WWVB RADIO CONTROLLED TIME

The NIST (National Institute of Standards and Technology) radio station (WWVB) is located in Ft. Collins, Colorado. It 
transmits an exact time signal continuously to most of the continental United States at 60 KHz frequency. The 
Atomic Time Clock in your weather station can receive this WWVB signal through the internal antenna from up to 2,000 miles 
away. Due to the nature of the Earth’s ionosphere, reception can be limited during the daylight hours. The radio controlled clock
will search for an alternate station that receives the atomic time signal from the NIST Atomic clock in Boulder, Colorado.
The WWVB tower icon on the unit’s display will flash indicating a radio signal reception from the WWVB station. If the tower 
icon is not fully lit, or if the time and date are not set automatically, please consider the following: 

• During night-time hours, atmospheric disturbances are typically less severe and radio signal reception may improve. A single 
  daily reception is sufficient enough to keep the clock accuracy within 1 second.
• Make sure the unit is positioned at 8 feet (2 meters) distance from any interference source such as a TV, computer monitor, 
  microwave, etc.
• Within concrete wall rooms such as basements or office buildings, the received signal may be weakened. Always place the 
  Projection Clock near the window for better reception. 

Once the atomic time signal is received, the date and time will be set automatically, and the       icon will appear.
After the clock is set manually, place the main unit by the window for the better reception. The atomic clock receiver is 
programmed that it will continue to search for the atomic time signal daily for every hour between 1:00 am and 4:30 am. 
Once the time signal has been successfully received, the time and date will be updated automatically.
To enable or disable the atomic time receiver:
• Press and hold UP ?  - if atomic time reception is activated, a triangular tower icon will start flashing next to the clock icon. If 
  reception is disabled, the triangular tower icon will disappear.

16

Содержание TE827W

Страница 1: ...TE827W USER MANUAL PROFESSIONAL WEATHER STATION 1...

Страница 2: ...ustomizing your Weather Station Using Different Weather Modes Pressure and Weather Forecast Mode Clock and Alarm Mode Manual Settings Temperature and Humidity Mode Rain Mode Wind Mode Maintenance Trou...

Страница 3: ...performance telescopes at affordable prices Meade Instruments now brings that same passion for innovation and high performance to its own line of precision feature rich weather stations Please read th...

Страница 4: ...mpartment Rain Gauge bucket Bucket see saw mechanism Protective screen Anemometer Consists of Wind Cups Wind Vane Anemometer arm Anemometer base Mounting hardware 4 screws for securing rain gauge to t...

Страница 5: ...display if any During an initial setup place the main unit close to the remote weather sensors After reception is established all of the remote readings will appear on the main unit s display positio...

Страница 6: ...ws provided when mounting the thermo hygrometer sensor on the wall Placement tips The remote thermo hygrometer sensor should be placed in the area with a free air circulation and sheltered from the di...

Страница 7: ...ompartment Replace the battery compartment door and secure the screws Insert the funnel shaped top into the rain gauge bucket and secure it into place by turning the knobs clockwise Mounting Make sure...

Страница 8: ...ATTERY COMPARTMENT Holds 2 AA size batteries G WALL MOUNT SCREW OPENINGS Allows securing the anemometer in place H BATTERY COVER Allows securing 2 AA size batteries on the anemometer base Assembly Wit...

Страница 9: ...ordance with the geographical information entered by the user Moon Phase calendar and historical data for the past and future 39 days Dual crescendo alarms with programmable snooze Weather Weather for...

Страница 10: ...he display functions will be locked allowing setting your local altitude or sea level pressure parameters The locked display will show the pressure and weather forecast icon and abbreviation hPa mBar...

Страница 11: ...mode Locks in set parameters Manually selects the channel for receiving temperature and humidity sensor data Enables the temperature and humidity channel auto scan mode E MEMORY Records moon phase tem...

Страница 12: ...Ch2 or Ch3 are provided by external sensor transmitters Displays Temperature and humidity readings for indoor and selected external channel Comfort level indication Predetermined level Dew point temp...

Страница 13: ...ing Pressure Parameters during initial setup IMPORTANT During the main unit initial setup after main unit powered up all of the functions in Pressure and Weather Forecast mode will be locked for a sho...

Страница 14: ...story for the past 24 hours in hour increments If no buttons are pressed for 5 seconds the unit will automatically return to the Pressure and Weather Forecast Mode Viewing the Pressure Temperature and...

Страница 15: ...nd longitude programming mode Setting USR latitude longitude If you selected the USR as a city code you will be prompted to enter the latitude longitude Time Zone and select Daylight Savings Time on o...

Страница 16: ...ins Colorado It transmits an exact time signal continuously to most of the continental United States at 60 KHz frequency The Atomic Time Clock in your weather station can receive this WWVB signal thro...

Страница 17: ...Humidity Mode press the SET button to recall temperature and relative humidity or dew point and relative humidity Set the Temperature in Celsius or Fahrenheit Does not affect Wind Chill In Temperature...

Страница 18: ...infall Alert Mode press the ALARM CHART to disable the alert WIND MODE The wind direction is shown by an animated compass display Its angle can be displayed as compass points i e NW or in bearings sta...

Страница 19: ...freely and are free from dirt debris and spider webs Rain Gauge Checking and cleaning the rain sensor in a timely manner will maintain an accuracy of the precipitation measurements Detach the protect...

Страница 20: ...e electronic circuits Do not subject the product to excessive force shock dust temperature or humidity which may result in malfunctions shorter lifespan damaged batteries and damaged parts Do not tamp...

Страница 21: ...C Can YVR 8 SU St Louis Mo STL 6 SU Washington D C DCA 5 SU Tampa Fla TPA 5 SU Vancouver Canada VAC 8 SU Toronto Ont Can YTZ 5 SU World Cities City Code Zone DST City Code Zone DST t e s f f O t e s...

Страница 22: ...n Italy MIL 1 SE Singapore Singapore SIN 8 NO Montevideo Uruguay MVD 3 SM Sofia Bulgaria SOF 2 SE Moscow Russia MOW 3 SK Stockholm Arlanda ARN 1 SE Sweden Munich Germany MUC 1 SE Sydney Australia SYD...

Страница 23: ...rating Range 0 to 99 Resolution 1 Accuracy 5 Sampling Interval 10 seconds Transmitting Interval around 47 seconds Wind Direction Range 0 to 360 Resolution 22 5 Accuracy 11 25 Starting Threshold 3mph 4...

Страница 24: ...the equipment off and on the user is encouraged to improve or correct turning the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separati...

Страница 25: ...nt detailing the nature of the claimed defect as well as the owner s name address phone number and a copy of the original sales invoice This warranty is not valid in cases where the product has been a...

Страница 26: ...Meade Instruments Corp 27 Hubble Irvine CA 92618 U S A 2011 Meade Instruments Corp All Rights Reserved All user manual contents and information are subject to change...