Connect the condensate hose (16mm diameter) and ensure that the water is flowing downhill with no 
kinks or blockages. You have the choice of fitting the drain on the right or left side. The hose on the 
right is pre-fitted, if you wish to change to the left, remove the bung from the left and swap it with the 
hose on the right.  

 

 

 

Содержание MeacoWall 108B

Страница 1: ...truction Manual MeacoWall 53B W MeacoWall 84B W and MeacoWall 108B W Dehumidifiers Please read this instruction manual before using the dehumidifier and keep safe for future reference Thank you for ch...

Страница 2: ...r cannot fall and cause injury Keep Out of Water Never operate the unit in pooled or standing water as this may create a risk of injury from electrical shock Do not store or operate outdoors If electr...

Страница 3: ...installed operated or stored in a non ventilated area then the room must be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the re...

Страница 4: ...ent local regulations non UK The unit is supplied without a plug and is expected to be connected to a fused spur by a qualified electrician following local regulations and laws Please refer to the uni...

Страница 5: ...ehumidifier to dry a room and reach the desired relative humidity depends on the environmental conditions prevailing within the room For example the number of air changes with outside any sources of m...

Страница 6: ...CATION Please keep the dehumidifier upright at all times prior to installation If the dehumidifier is inclined greater than 60 degrees then the dehumidifier should only be turned on 24 hours after it...

Страница 7: ...Make sure the wall that the dehumidifier is being fixed to is strong enough to support its weight This dehumidifier must be used exclusively for drying the air If the dehumidifier has been in a horizo...

Страница 8: ...s fitted ready to come out of the right of the dehumidifier as you look at it from behind If you wish to move the drain to the other side then you can do so by removing the side covers this should onl...

Страница 9: ...he water is flowing downhill with no kinks or blockages You have the choice of fitting the drain on the right or left side The hose on the right is pre fitted if you wish to change to the left remove...

Страница 10: ...The display will dim after 90 seconds of no keys being pressed ON OFF BUTTON Press the ON OFF button to turn the dehumidifier on or off CHILD LOCK Press the ON OFF button for five seconds to activate...

Страница 11: ...d button quickly to choose between one of three different fan speeds low 1 medium 2 and high 3 The default setting for the fan speed is Fan Speed 1 Low FAN SPEED OPTIONS CONTINOUS Hold down the Fan Sp...

Страница 12: ...l start to dehumidify again DEFROST MODE This dehumidifier is equipped with an automatic hot gas defrosting system When operating in low temperatures the surface of the evaporator will accumulate fros...

Страница 13: ...ing the dehumidifier from the wall and without tilting the dehumidifier The image below only shows the dehumidifier on its side for clarity To remove the filter press the two single red buttons to the...

Страница 14: ...n a wet area must comply with local laws We recommend electrical installation and servicing by a qualified electrician only OPERATING CONDITIONS This dehumidifier can be operated within an ambient tem...

Страница 15: ...50Hz 220 240V 50Hz Air Flow m h 500 650 800 Noise Level dB A 44 44 46 Power Consumption kW 0 892 1 095 1 700 Running Current amps 4 1 5 1 7 9 Start up Current amps 21 25 39 Refrigerant R32 R32 R32 Dry...

Страница 16: ...16 PERFORMANCE CURVES MEACOWALL 53B W DEHUMIDIFIER MEACOWALL 84B W DEHUMIDIFIER MEACOWALL 108B W DEHUMIDIFIER...

Страница 17: ...s normal and is not a fault Compressor is not on The dehumidifier has just turned on Wait 3 minutes for the compressor to start up Unit is in defrost mode defrost symbol appears on the display This is...

Страница 18: ...bnormal levels of chlorine would be anything above 2ppm and or a super chlorination above a maximum of 30ppm over a 24 hour period STORAGE If the machine will not be used for a long period of time tak...

Страница 19: ...d in the user s manual or by neglect 6 The warranty does not cover faults caused by dirt or by third party products 7 The warranty does not cover accidental damage 8 All claims for compensation includ...

Страница 20: ...m to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and...

Отзывы: