The MeacoDry ABC 10L, 12L and 20L dehumidifiers use the new R290 refrigerant gas to
comply with European Environmental Directives. R290 is kinder to the environment and
is part of attempts to reduce global warming as it has a low greenhouse effect (GWP).
When using the MeacoDry ABC 10L, 12L and 20L dehumidifiers you must take into account the
following:
•
This dehumidifier uses about 35 grams of R290 refrigerant in the 10L model, 45 grams of R290
refrigerant in the 12L model and 75 grams of R290 refrigerant in the 20L model, which is
flammable. Therefore, it is part of a sealed system and must only be serviced by a trained
Meaco engineer.
•
Do not use or store this dehumidifier in a room smaller than 4m² to prevent a fire or explosion
hazard if there is a leak of refrigerant and the gas comes into contact with an ignition source.
•
Do not use in a room with any continuous sources of ignition, for example open flames, gas
fires or hobs, cigarettes or any other sources of ignition.
•
If the dehumidifier is installed, operated or stored in a non-ventilated area, then the room must
be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or
explosion due to ignition of the refrigerant caused by electric heaters, cookers, or other sources
of ignition.
•
R290 refrigerant gas is odourless.
•
Do not puncture either during the units working life or after. At the end of life dispose of following
local recycling regulations.
•
If there is any damage to the dehumidifier then do not use it and contact Meaco or your retailer.
•
As with all dehumidifier, always keep upright and leave the dehumidifier standing upright for six
hours before using it upon receipt.
Failure to comply with these instructions could result in fire, damage to property, serious
injury or potentially death.
Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued
by a national accredited organisation that ensures competence in handling flammable refrigerants
according to a specific evaluation recognised by national associations in the industry and compliant
with the latest R290 guidance.
Servicing should only be carried out by a Meaco approved engineer using original Meaco parts to
prevent damage to the unit and potential injury to the engineer.