SAFTEY INFORMATION 

----------------------------------------------------------------------------------------------------------------------------- ----------

 

This dehumidifier must not be used in rooms under the following conditions:  
- Potentially explosive atmosphere 
- Aggressive atmospheres 
- Featuring a high concentration of solvents  
- An extremely high ratio of dust

 

 

 

Keep Children Away: 

Do not allow children to play with or around this unit, which could result in injury. 

Be sure the unit is inaccessible to children when not attended. This appliance is not intended for use 
by  person  (including  children)  with  reduced  physical,  sensory  or  mental  capabilities,  or  lack  of 
experience and knowledge, unless they have been given supervision or instruction concerning use of 
the appliance by a person responsible for their safety.

 

Keep Unit Grounded:

 Always operate the unit with a grounding plug and a grounded electrical outlet. 

A grounding plug is an essential safety feature that helps reduce the risk of shock or fire. 

 

Protect  Power Cord from Damage: 

Never operate  a unit with a  damaged power cord, as this may 

lead to electrical or fire hazards. If the power supply cord is damaged, it must be replaced by a cord of 
the same type and amperage rating. 

 

Extension Cords: 

Extension cords must be grounded and able to deliver the appropriate voltages to 

the unit. 

 

Handle with  Care

:  Do  not  drop,  throw  or  crash  the  dehumidifier.  Rough  treatment can  damage  the 

components or wiring and create a hazardous condition. 

 

Run on Stable Surface: 

Always operate the unit on a stable, level surface, for example the floor or a 

strong counter, so that the dehumidifier cannot fall and cause injury. 

 

Keep Out of Water: 

Never operate the unit in pooled or standing water, as this may create a risk of 

injury from electrical shock. Do not store or operate outdoors. If electrical wiring or components become 
wet, thoroughly dry them before using the unit. If in doubt do not use the  dehumidifier and consult a 
qualified electrician or a Meaco approved engineer. 

 

Keep Air Intakes Clear: 

Do not clog or block the air intakes by placing the dehumidifier too close to 

curtains, walls or anything that will restrict the air inlet. This may cause the unit to overheat and result 
in a fire or electrical hazard. 

 

Keep Electrical Components Dry: 

Never allow water inside the 

dehumidifier’s electrical components. 

If  these  areas  become  wet  for  any  reason,  thoroughly  dry  them  before  using  the  dehumidifier.  If  in 
doubt, do not use the dehumidifier and consult a qualified electrician or a Meaco approved engineer. 

 

The operator must make the operating instruction available for the user and make sure that the user 
does understand the manual.   

 

 

 

 

 

 

Содержание MeacoDry ABC 10L

Страница 1: ...ifier Instruction Manual MeacoDry ABC 10L 12L and 20L Dehumidifier Please read this instruction manual before using the dehumidifier and keep safe for future reference Thank you for choosing Meaco we...

Страница 2: ...the appropriate voltages to the unit Handle with Care Do not drop throw or crash the dehumidifier Rough treatment can damage the components or wiring and create a hazardous condition Run on Stable Su...

Страница 3: ...tilated area then the room must be designed to prevent the accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric heaters cook...

Страница 4: ...minal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the...

Страница 5: ...humid air from the room in and across a filter and then through an evaporator Here the air is cooled below dew point so that the water vapour of the air forms a condensate on the coils which flows in...

Страница 6: ...from www meaco com Handle Air inlet and filter Control panel Air outlet Water tank Continuous drainage outlet Legs Front cover Power cord Power button Timer button Sleep mode Humidistat button Fan sp...

Страница 7: ...t and filter Air outlet Wheels Continuous drainage outlet Power cord Laundry mode Laundry mode button Fan speed button Child lock Timer button Sleep mode Power button Up arrow Down arrow High fan spee...

Страница 8: ...n using the power button The buttons on the control panel are sensitive Press the timer button quickly and firmly Do not hold the timer button down as the dehumidifier will go into sleep mode see belo...

Страница 9: ...r 6 hours After 6 hours the dehumidifier will switch off until it is manually switched on again Laundry mode can be switch off at any point by pressing the laundry button or turning the dehumidifier o...

Страница 10: ...g on the display will show the current relative humidity level in the environment the dehumidifier is being used in When the humidistat button on the 10L and 12L model or the down arrow on the 20L mod...

Страница 11: ...arget humidity level of 50 rh or 55 rh and positioning the dehumidifier in a central position within your home for example the landing or hallway If you have more of a problem in one area of your hous...

Страница 12: ...from the dehumidifier Secure the 14mm hose onto the internal outlet pipe Once the hose is in place put the water tank back into the dehumidifier for continuous drainage to work the water tank must alw...

Страница 13: ...L 12L and 20L WATER TANK The water tank is found on the front of the unit on the 20L model and at the back of the unit on the 10L and 12L model In order to empty the water tank simply pull the tank ou...

Страница 14: ...e clogged with dust and dirt particles The filter must be cleaned a minimum of every two weeks not doing so could invalidate the units warranty Please use the following steps Remove the filter it can...

Страница 15: ...80 rh Air flow nominal 105m hour 105m hour 145m hour Noise level at one metre Maximum 40dB A Maximum 40dB A Maximum 44dB A Power Supply 230V 50Hz 230V 50Hz 230V 50Hz Rated power consumption 155W 155W...

Страница 16: ...unit does not collect water The water tank is full Empty the water tank and reinsert The water tank has not been inserted correctly Make sure the water tank is securely in place The filter is blocked...

Страница 17: ...t feel cooler because it is moving this is the same as the air from a fan The room temperature will not be reduced by the unit and it is not cooling the air The display is not showing the target humid...

Страница 18: ...as described in the user s manual or by neglect 6 The warranty does not cover faults caused by dirt or by third party products 7 The warranty does not cover accidental damage 8 All claims for compens...

Страница 19: ...harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return...

Отзывы: