Page 25
Appendix | Digital Interface RS485
ACC5703
A 4.2.1
Reading Measurement Data
Master: Request data
Byte:
SD
DA
SA
FC
FCS
ED
Value:
0x10
x
x
0x4C
x
0x16
FCS
Slave: Response data
Byte:
SD
LE
LE
rep
SD
rep
DA
SA
FC
Data[]
FCS
ED
Value:
0x68
x
x
0x68
x
x
0x08
x
x
0x16
FCS
Designations
SD
Start Delimiter
(0x10: datagram without data, 0x68: datagram with variable length)
LE
Length (number of bytes without SD, LE, LE rep, SD rep, FCS, ED)
LE rep
LE repeated
SD rep
SD repeated
DA
Destination Address (default 0x7E = 126)
SA
Source Address (e. g. 0x01)
FC
Function Code
FCS
Checksum
(sum of all bytes without SD, LE, LE rep, SD rep, FCS, ED, overflow at 256)
ED
End Delimiter
Data[]
Measurement data, variable number, little endian
The measurement data consists of one status byte, one measured values counter, number of measured val-
ues, and the measured data. The measured values counter increases continuously with each sampled value.
It represents the number of measured values buffered in the sensor since the last enquiry by the master and
therefore represents the number of the measured values transmitted in this package (floats).