Me inertialSENSOR ACC5703 Скачать руководство пользователя страница 1

MICRO-EPSILON MESSTECHNIK GmbH & Co. KG
Königbacher Str. 15 · 94496 Ortenburg / Germany
Tel. +49 (0) 8542 / 168-0 · Fax +49 (0) 8542 / 168-90
[email protected] · www.micro-epsilon.com

ACC5703

Operating Instructions

inertial

SENSOR 

ACC5703

Содержание inertialSENSOR ACC5703

Страница 1: ...ILON MESSTECHNIK GmbH Co KG K nigbacher Str 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 info micro epsilon de www micro epsilon com ACC5703 Operating Instructions inertialSENSO...

Страница 2: ...ICRO EPSILON MESSTECHNIK GmbH Co KG K nigbacher Strasse 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 e mail info micro epsilon de www micro epsilon com 3 axes acceleration senso...

Страница 3: ...livery 12 3 1 Unpacking Included in Delivery 12 3 2 Storage 12 4 Installation and Assembly 13 4 1 Sensor Cable Assembly 13 4 2 Sensor Assembly 13 4 3 Pin Assignment 15 4 4 Current and Voltage Output 1...

Страница 4: ...ies 23 A 2 PC Software sensorTOOL 23 A 3 Factory Settings 23 A 4 Digital Interface RS485 24 A 4 1 Hardware Interface 24 A 4 2 Protocol 24 A 4 2 1 Reading Measurement Data 25 A 4 2 2 Example Transmissi...

Страница 5: ...ulations for electrical equipment Risk of injury Damage to or destruction of the sensor The supply voltage must not exceed the specified limits Damage to or destruction of the sensor No sharp or heavy...

Страница 6: ...4496 Ortenburg Germany The measuring system is designed for use in industrial environments and meets the requirements 1 4 Intended Use The ACC5703 is designed for use in industrial applications It is...

Страница 7: ...ge 7 Safety ACC5703 1 5 Proper Environment Protection class 1 IP 67 Operating temperature 40 85 C 40 185 F Storage temperature 40 85 C 40 185 F Ambient pressure Atmospheric pressure 1 With M12 connect...

Страница 8: ...The included MEMS Element converts the acceleration into a usable electric signal z z x x y y Fig 1 Three axes acceleration sensor 2 2 Structure and Electrical Connection The sensor is ready for oper...

Страница 9: ...A g Voltage 1 V g Zero 12 mA or 2 5 V Linearity Typ 0 45 FSO Frequency range 0 1000 Hz configurable Sampling rate Up to 4 kHz Cross axis sensitivity 1 FSO Temperature stability Typ 0 2 mg K Supply vol...

Страница 10: ...luminum Installation Screw connection via mounting holes M4 Connection M12 connector 8 pin Start up time 500 ms FSO Full Scale Output All specifications valid at a room temperature of 25 C 77 F Articl...

Страница 11: ...rinciple Technical Data ACC5703 Response time Sampling frequency Hz Time ms 4000 0 88 2000 1 25 1000 2 03 500 3 51 250 6 52 125 12 59 62 5 24 43 31 25 47 84 15 625 96 5 7 813 189 83 3 906 384 56 Fig 2...

Страница 12: ...and ensure that the goods are forwarded in such a way that no damage can occur Check the delivery for completeness and shipping damage immediately after unpacking If there is damage or parts are missi...

Страница 13: ...sensor cable against damage Damage or destruction of the cable failure of the measuring device Ensure that the coupling nuts of the connectors are firmly tightened Damage or destruction of the cable f...

Страница 14: ...ge 14 Installation and Assembly ACC5703 12 47 53 2 09 5 5 22 5 5 22 12 47 76 2 99 12 5 49 6 24 24 94 26 5 1 04 Mounting holes for M4 screws Fig 4 Dimensional drawing dimensions in mm inches not to sca...

Страница 15: ...assignment of the 8 pin A coded female connector 1 SA Connector 2 PCx 8 M12 Power supply and output cable see A 1 4 4 Current and Voltage Output The sensor makes the acceleration value available as an...

Страница 16: ...separate pins depending on the configuration using the software tool of Micro Epsilon In this process the symmetrical measurement range in the unit g is scaled to the respective analog range The sensi...

Страница 17: ...10 s Edge triggered switching when reaching the level considering the minimum hold time see Fig 13 Edge triggered with delay switching after specified time during which the level is reached permanentl...

Страница 18: ...vels in switching operation Voltage in V t in s 0 5 0 0 5 1 1 5 2 5 3 5 4 5 2 3 4 5 10 15 20 25 30 35 40 45 50 Trigger Trigger Fig 12 Rising and falling edge of the voltage output in switching mode t...

Страница 19: ...range in order to match the re spective application The high pass is configured to reduce influences of low frequencies especially to hide earth acceleration The low pass is configured to hide distur...

Страница 20: ...3 906 9 296e 6 0 009648 Fig 15 Table dependency between sampling rate and low and high pass settings 1 Digital interface RS485 is enabled only up to 1000 Hz sampling rate At higher rates only the anal...

Страница 21: ...owever if de fects occur despite our careful quality control MICRO EPSILON or your dealer must be notified immediately The liability for material defects is 12 months from delivery Within this period...

Страница 22: ...KG K nigbacher Str 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 info micro epsilon de www micro epsilon com 8 Decommissioning Disposal Remove the power and output cable from the...

Страница 23: ...drag chain use 10 m long PC15 8 M12 Power supply and output cable 15 m long PC2 8 Sub D Power supply and output cable with USB RS485 converter 2 8 m long A 2 PC Software sensorTOOL You will find the...

Страница 24: ...resistance of 120 is required between the A and B line of the RS485 interface at the begin ning and the end of the RS485 bus A terminating resistor of the RS485 line is not incorporated in the sensor...

Страница 25: ...SD repeated DA Destination Address default 0x7E 126 SA Source Address e g 0x01 FC Function Code FCS Checksum sum of all bytes without SD LE LE rep SD rep FCS ED overflow at 256 ED End Delimiter Data...

Страница 26: ...1 kHz 19 values 1 ms 19 ms Example 250 Hz 19 values 4 ms 76 ms If the enquiries are not made in time error flag 0x01 is set in the status byte The measurement is continued anytime i e the values in t...

Страница 27: ...ckage 8 bit Data 6 Padding byte 8 bit Data 7 Padding byte 8 bit Data 8 Measured value 1 bit 0 7 Float 32 bit Data 9 Measured value 1 bit 8 15 Data 10 Measured value 1 bit 16 23 Data 11 Measured value...

Страница 28: ...Measured value 1 y axis bit 8 15 Data n 6 Measured value 1 y axis bit 16 23 Data n 7 Measured value 1 y axis bit 24 31 Data n m m 4 Data 5 Measured value 1 z axis bits 0 7 Float 32 bit Data n m 1 Meas...

Страница 29: ...0x4C 0xCB 126 1 76 203 no overflow at 256 Slave Response data Byte SD LE LE rep SD rep DA SA FC Data FCS ED Value 0x68 1B 1B 0x68 0x01 0x7E 0x08 x 0x67 0x16 FCS 4 measured values 4 x float 4 x 4 bytes...

Страница 30: ...N MESSTECHNIK GmbH Co KG K nigbacher Str 15 94496 Ortenburg Germany Tel 49 0 8542 168 0 Fax 49 0 8542 168 90 info micro epsilon de www micro epsilon com X9751392 A011068HDR X9751392 A01 MICRO EPSILON...

Отзывы: