hysteresis is 2.5% of the measurement range.
At outputs F1 and F2 voltages of  0.03 volts up to 1 volts are detected.

Below the switching thresholds the relays are in the working state, the relay contacts are 
opened. The corresponding light-emitting diodes (LED) light below the switching 
thresholds.
On exceeding the thresholds or with the failure of the supply voltage U

B

 the relay contacts 

close. The exceeding of the threshold is signalled by the switching off of the LED.
Special variants as U/I-converters or peak value display with voltage input 0...5V are 
optionally available.

Functional Diagram

Through the layout of jumpers two operating modes ("A" and "B") can be selected:

Mode "A" 

: (actual value-mode)

Signal-sequence: Amplification, peak value storage
The threshold indicator reacts to the actual value.
The actual value is shown on terminal 6.
The peak value is shown on terminal 7.

Mode "B"

: (Peak value-mode)

Signal-sequence: Peak value storage, amplification
The threshold indicator reacts to the peak value.
The peak value is indicated (with the amplification selected) on terminal 6.
At terminal 7 the peak value with the amplification "1" is indicated.

The maximum output voltage on the peak value display (terminal 7) is limited to 5 
volts. The maximum output signal on terminal 6 amounts to +10 volts.

10

Instruction Manual

Sensor

1
2

3
4

Threshold
switch 1

Threshold
switch 2

13
14

15
16

6

4...20 mA

5

7

Peak
detector

Selectable
Gain: 

1x, 2x, 4x, 10x

10

12

9 Tare

11

Power Supply
GND

8

4

5

6

1

2

3

Mode

A

B

1

2

3

4

5

6

4

5

6

1

2

3

Содержание GSV-1

Страница 1: ...Straingage Bridge Amplifier GSV 1 Version July 09 2007 ME Me systeme GmbH Neuendorftstr 18a Tel 49 3302 559 282 DE 16761Hennigsdorf Fax 49 3302 559 141...

Страница 2: ...iagram 10 Pin Configuration 11 Adjustment of Input Sensitivity 11 Layout of Jumpers 12 Dimensions 12 Option EP cConnection of an External Potentiometer 12 Aluminum housing GSV 1A 14 Pin Configuration...

Страница 3: ...Strain Gage Measuring Amplifier GSV 1 Instruction Manual 3...

Страница 4: ...ply up to 4 parallel connected weighing cells with 350 ohm bridge resistance each and is therefore eminently suitable for applications in weighing technology The option GSV H can supply for 8 weighing...

Страница 5: ...ification stages 1x 2x 4x 10x and trimmer 1x 10x 5V 10V 4 20mA 0 20mA GSV 1H amplification switching Option TR stepless amplification setting via trimmer potentiometer HSW Version Top hat rail housing...

Страница 6: ...ce optional for GSV 1H 5 6 7 5 47 10V 4 20mA 0 20mA V V Ohm Operating voltage Nominal range Operating range Nominal range GSV 1A GSV 1A 12 0 24 10 5 28 GSV 1L 10 5 16 or 18 28 V V V Current consumptio...

Страница 7: ...can be switched 1 2 4 10 times with internal jumpers If the input signal is negative output follows up to 0mA the input signal beyond it remains at 0mA Pin Configuration Pins 1 2 US US Bridge supply...

Страница 8: ...t voltage at sensitivity option 2 mV V Output voltage at sensitivity option 3 5 mV V 1 1 5 volts at 2 mV V 5 volts at 3 5 mV V 2 2 5 volts at 1 mV V 10 volts at 2 mV V 5 volts at 1 75 mV V 10 volts at...

Страница 9: ...rol signal between 5 volts and 24 volts is fed in In this way the zero point of the force sensor will be balanced and the peak value storage will be reset to zero Through internal jumpers the amplific...

Страница 10: ...an be selected Mode A actual value mode Signal sequence Amplification peak value storage The threshold indicator reacts to the actual value The actual value is shown on terminal 6 The peak value is sh...

Страница 11: ...d of the supply voltage and the ground of the output signal are connected to terminal 8 Adjustment of Input Sensitivity The input sensitivity can be adapted by displacement of the jumper The input sen...

Страница 12: ...he ground 12 Instruction Manual 99 0 22 5 1 2 3 4 5 6 7 8 91 01 11 2 1 31 41 51 6 GSV 1HSW SW 1 SW2 SW 1 SW2 Depth 114 5mm for mounting on carrying rails according to EN50022 On exceeding the threshol...

Страница 13: ...tput 0 10V is realised with the amplification level 2 b In the standard design the device is equipped with a Bessel filter 2nd order 250 Hz c The calibration by the manufacturer is carried out either...

Страница 14: ...o setting terminal 8 is connected to the voltage supply or a control signal between 5 volts and 24 volts is applied Amplification can be switched 1 2 4 10 times by means of jumpers Pin Configuration T...

Страница 15: ...factor Output voltage at sensitivity option 2 mV V Output voltage at sensitivity option 3 5 mV V 1 1 5 volts at 2 mV V 5 volts at 3 5 mV V 2 2 5 volts at 1 mV V 10 volts at 2 mV V 5 volts at 1 75 mV...

Страница 16: ...Option 718 plug The measuring amplifier GSV 1A is also supplied with plugs of type type 718 The pin configuration is the same as that of module housing GSV 1M 16 Instruction Manual...

Страница 17: ...put are connected to the round plug B pin contacts For zero setting Pin 4 is connected to the voltage supply Pin 1 or a control signal between 5 Volt and 24 Volt is applied Dimensions Pin Configuratio...

Страница 18: ...oltage supply 2 UD positive differential input 2 GND ground 3 US positive bridge supply 3 5V stabilized 4 US negative bridge supply GND 4 internally reserved 5 GND ground 5 internally reserved 6 UA an...

Страница 19: ......

Страница 20: ...en Alle Angaben beschreiben unsere Produkte in allgemeiner Form Sie stellen keine Eigenschaftszusicherung im Sinne des 459 Abs 2 BGB dar und begr nden keine Haftung Made in Germany Copyright 1999 2007...

Отзывы: