MDS 05-2708A01, Rev. D
MDS TransNET I&O Guide
37
All units default to Remotes; other modes must be specifically programmed
with the
MODE
command.
If
MODE X
is used, the
MODE X
radio should be programmed with an
Extended Address (
XADDR
). Units that need to hear this
MODE X
radio must
be programmed with an appropriate
XPRI
and/or
XMAP
value.
MRSSI [NONE, –40...–90]
Minimum RSSI for Mobile Operation
The
MRRSSI
command sets or displays the minimum RSSI level (dBm) of a
Master station’s signal to maintain synchronization. When the Master’s
signal falls below this level, the Remote will attempt to resynchronize with
the next Master it can hear within the same network—same Network Address
(
ADDR
)—and, meets the MRSSI level. See
“Mobile Operation Support” on
Page 62
for additional information.
OT [ON, OFF]
Output Trigger
The “output trigger” feature sets up a 1-second default delay on delivery of
RXD serial data, however, a receipt of RTS causes cancellation of timer
followed by immediate data delivery.
Hierarchy Rules:
• if
OT
= ON, RTS always cancels data delay and outputs immediately
• if
OT
= ON,
DEVICE
= DCE, and
RXD
= 0, data delay is 1 second or
until RTS
• if
DEVICE
= DCE, and
RXD
= N, data delay is N ms
• if
DEVICE
= CTS KEY, and
CTS
= N, data delay is N ms or until RTS
• if
DEVICE
= CTS KEY overrides
RXD
,
RXD
overrides
OT
default.
OWM [xxxxx]
“Owner’s Message”
The
OWM
command sets or displays an optional owner’s message, such as the
system name. The entry can contain up to 30 characters.
OWN [xxxxx]
“Owner’s Name”
The
OWN
command sets or displays an optional owner’s name, such as the
site name. The entry can contain up to 30 characters.
PORT [RS232, RS485]
Data Interface Port Signaling Standard
Select or identify the current data port (
DATA
connector) interface signaling
mode:
RS232
or
RS485
. This is the port though which the payload data will