26
MDS TransNET I&O Guide
MDS 05-2708A01, Rev. D
ASENSE
Details Page 29
Current sense of the alarm output.
BAUD
Details Page 29
Data communication parameters. Example:
BAUD 9600 8N1
BUFF
Details Page 30
Data buffering mode: ON = seamless data,
OFF = fast byte throughput
CODE
Details Page 30
Security/encryption operational status.
“NONE” (Inactive), or “ACTIVE”
CTS
Details Page 31
CTS delay in milliseconds (0–255 ms)
CTSHOLD
Details Page 32
“Hold time” that CTS is present following last
character from DATA port.
DEVICE
Details Page 32
Device behavior
Alternatives: DCE and CTS KEY
HOPTIME
Details Page 34
Hop-time value in milliseconds (ms).
LPMHOLD
Details Page 36
Time (0-1000 ms) provided to give an RTU
time to respond before the radio goes to sleep.
MODE
Details Page 36
Current operating mode:
M = Master
R = Remote
X = Extension (Repeater)
MRSSI
Details Page 37
Minimum RSSI level required to preserve syn-
chronization with a Master radio for Remotes
in mobile service.
OWM
Details Page 37
Owner’s message or site name
OT
Details Page 37
Status (ON/OFF) of the 1-second delay on
delivery of RXD serial data.
OWN
Details Page 37
Owner’s name or system name
PORT
Details Page 37
Current data port (DATA connector) interface
signaling mode: RS232 or RS485
PWR
Details Page 38
Forward power-output setting in dBm
Table 10. Operating Status—Display Only
(Continued)
Command
Description
Содержание TransNET 2400