background image

© MDM INC.

WWW.MDMINC.COM

Efficiency and Longevity.

PROUDLY MADE

IN THE USA

© MDM INC.

WWW.MDMINC.COM

Efficiency and Longevity.

PROUDLY MADE

IN THE USA

INSTALLATION AND SERVICE MANUAL

                               TYPE:

     SELF PRIMING CENTRIFUGAL

                          MOTOR:

     NEMA 56Y

            HORSEPOWER:

     1/3, 1/2 (1750 RPM)  2 (3450 RPM)

          PRIMER ALPHA:

     2” FNPT INLET AND DISCHARGE WITH 2” & 2 1/2” SLIP ADAPTERS

  PRIMER CHAMPION:

     2” FNPT INLET AND DISCHARGE WITH 2” SLIP ADAPTERS

      MATERIAL:

     GLASS-FILLED POLYPROPYLENE

   HARDWARE:

     STAINLESS STEEL HARDWARE

         

OPTIONS:

     SALTWATER SERVICE

  ACCESORIES:

     SWING CHECK VALVES (1.5”, 2”, 3”)

WARNING:

 Please read completely before you install or operate your new pump. This is an external “out-of-pond” pump.

It is NOT submersible. Do NOT allow this pump to become submerged. Never run dry. 

Model

3700PRM21 4900PRM21 6600PRM24 6800PRM19

7800PRM24

6300PRM77

8100PRM81

9300PRM83

INLET

2”

2”

2”

2”

2”

2”

2”

2”

DISCHARGE

2”

2”

2”

2”

2”

2”

2”

2”

MAX FLOW (gph)

3700

4900

6600

6800

7800

6300

8100

9300

MAX HEAD (feet)

21’

21’

24’

19’

24’

77’

81’

83”

MAX POWER (watts)

228

310

457

369

504

1496

1807

2222

MAX CURRENT (amps)

2.76 @115V

3.37 @115V 4.61 @115V 3.93 @115V

5.02 @115V

8.7 @ 230

9.8 @ 230

11.4 @ 230

VOLTS

115/230

115/230

115/230

115/230

115/230

230 /115

230 /115

230 /115

MOTOR HP

1/2, 1/3

1/2, 1/3

1/2, 1/3

1/2, 1/3

1/2, 1/3

2

2

2

MOTOR TYPE

56Y

56Y

56Y

56Y

56Y

56Y

56Y

56Y

MOTOR ENCLOSURE

TEFC

TEFC

TEFC

TEFC

TEFC

ODP

ODP

ODP

®

 

PRIMER

®

 

PRIMER

MAINTENANCE                                                                                           WARNING: EYE PROTECTION IS STRONGLY RECOMMENED 

Lubrication

Motor -  Permanently Lubricated ball bearings - no service required.
Rotary Seal - Requires no lubrication after assembly.

     

 Symptom

      

Problem

      

Resolution

No Flow

Insufficient Prime

Prime system with water and purge all air from suction piping.
Install check valve.

Insufficient Power

Verify power supply and connection from panel to pump.
Verify proper voltage.  Some models are dual voltage (115/230).

Flow Restriction

Ensure valves are open.
Ensure plumbing is clear, including suction strainers, check valves, etc.
Verify check valve orientation and direction of permitted flow.
Clean out leaves or other debris from basket strainer (if applicable).

Insufficient Prime

Prime system with water and purge all air from suction piping. The primer series pumps use low 
RPM motors and achieving full system prime could take multiple hours.  

*This resolution pertains 

only to the Primer Champion and the Primer Alpha models. 

Air leak

Fix air leaks at fittings, connections, priming pot lid, etc. This typically occurs on the intake side. 

The priming pot lid o-ring can be lubricated with silicone grease.

System Incompatibility

Verify hydraulic compatibility: i.e. pump & pipe are sized for the system.

Low Flow

Air leak

Fix air leaks at fittings, connections, priming pot lid, etc. This typically occurs on the intake side. 

The priming pot lid o-ring can be lubricated with silicone grease.

System Incompatibility

Verify hydraulic compatibility: i.e. pump & pipe are sized for the system. 

Insufficient Power

Verify power supply and connection from panel to pump.
Verify proper voltage.  Some models are dual voltage (115/230).

Flow Restriction

Ensure valves are open.
Ensure plumbing is clear, including suction strainers, check valves, etc.
Clean out leaves or other debris from basket strainer (if applicable).

Insufficient Prime

Prime system with water and purge all air from suction piping.

Cavitation

Verify airtight plumbing on the suction plumbing especially fittings.
Clean out leaves or other debris from basket strainer (if applicable).
Increase pipe size where possible.
Decrease suction pipe length, reduce the number of elbows, etc.
Verify hydraulic compatibility: i.e. pump and pipe are sized for the system.

Sporadic Operation

Insufficient Power

Verify power supply and connection from panel to pump.

Verify proper voltage.  Some models are dual voltage (115/230).

Poor Ventilation

Ensure adequate aiflow over motor to prevent overheating.

Excessive Noise

Cavitation

Verify airtight plumbing on the suction plumbing especially fittings.
Clean out leaves or other debris from basket strainer (if applicable).
Increase pipe size where possible.
Decrease suction pipe length, reduce the number of elbows, etc.
Verify hydraulic compatibility: i.e. pump and pipe are sized for the system.

Insufficient Power

Verify power supply and connection from panel to pump.
Verify proper voltage.  Some models are dual voltage (115/230).

Flow Restriction

Ensure valves are open.
Ensure plumbing is clear, including suction strainers, check valves, etc.
Verify check valve orientation and direction of permitted flow.

PRIMER ALPHA

PRIMER CHAMPION

S/N: XXXX-XXXXXX

XXXXPRMXX

PRIMER CHAMPION

PRIMER ALPHA

PRIMER POWER

Gasgacinch

®

 is a registered trademark of Porter Manufacturing. Noryl

®

 is a registered trademark of the General 

Electric Company. Teflon

®

 is a registered trademark of DuPont Company. Sequence

®

 is a registered trademark of

MDM Incorporated.   

Compilation Installation Manual 2017.indd   Adobe Indesign CC 03-28-17

PLEASE FILL IN FOR FUTURE REFERENCE: 

MODEL:

 ___________________________

SERIAL NUMBER:

 ____________________

DATE PURCHASED:

 ___________________

* PLEASE FILL OUT THE WARRANTY REGISTRATION 
CARD INCLUDED WITH THIS PRODUCT OR ONLINE 
AT: WWW.MDMINC.COM

*The pump must be drained before servicing or if stored below freezing 
temperatures.  Periodic replacement of seals may be required due to normal 
carbon wear.

MDM INCORPORATED
3345 N. Cascade Ave • Colorado Springs, CO • 80907
Toll Free Phone (800) 447-8342 • Fax (866) 425-1346
www.mdminc.com • [email protected] 