background image

 

ICE FOG Compack

TM

 

User Guide120818, Rev: B/a 

9 / 19

 

OPERATING INSTRUCTIONS 

 

 

The  MDG  Low  Fog  Generators  are  quite  easy  to  operate  and  require  no  preventive 
maintenance. They are supplied with a removable remote control. A DMX Interface can be 
purchased as an option. 

When the MAIN POWER 115 or 230 VAC and the MAIN POWER SWITCH are applied, the 
generator  is  placed  in  stand-by  mode.  When  in  stand-by  mode,  most  of  the  electronic 
controls are off (except for the three types of fail-safe systems), waiting for the ON switch 
on the remote control to be activated. 

When the ON switch is pressed, the red LED indicating that the unit is working will lit, as 
well as the yellow LED called HEAT, indicating the start of the heating cycle which will last 
approximately 10 minutes. When the temperature reaches a pre-adjusted level called the 
READY level (indicated by a green LED), the HEAT yellow LED will turn off. 

The  Generator  is  ready  to  produce  low  fog.  Adjusting  the  fog  output  adjustment  can 
control the amount of the low fog emission. 

When  an  overheating  condition  is  detected,  or  if  the  internal  temperature  reaches  60°C 
(140°F),  a  safety  circuit  is  triggered.  This  circuit  removes  the  power  to  the  heating 
elements, preventing hazardous conditions 

The FOG ON signal (green LED) can be applied to produce low fog for as long as the ready 
level is reached and all other control parameters are within specifications. 

The 100% Duty cycle is continuous with specified line voltage, and will degrade with line 
voltage loss. If that is the case, reducing maximum operating pressure can compensate it. 

 

 

 

Содержание ICE FOG Compack

Страница 1: ...td M A D E IN CAN A D A F A B R IQU AU CA N A D A 10301 avenue Pelletier Montr al Qu bec Canada H1H 3R2 Tel 514 272 6040 800 663 3020 Fax 514 722 3229 www mdgfog com e mail info mdgfog com ICE FOG Com...

Страница 2: ...ICE FOG CompackTM User Guide120818 Rev B a 2 19 Intentionally left blank...

Страница 3: ...available under request for low pressure refrigerated liquid Carbon Dioxide low pressure cryogenic L CO2 Dewar We hope it will bring you long hours of satisfaction This product is available in many ve...

Страница 4: ...hree types of electronic fail safe systems are designed to protect against over and under heating conditions and against component failure The temperature is maintained within a narrow margin the HEAT...

Страница 5: ...valve is on Fog Output Delay Delay of 3 to 30 seconds Allowing to cool down the cold chamber of the Generator before producing low fog Fog Output adjustment Pressure regulator Gauge Maximum Operating...

Страница 6: ...Connector Green LED indicates that the Generator is READY to operate Fog switch with a Green LED indicator Power switch with the Red LED HEAT yellow LED indicator 1 The LED turns on and off from time...

Страница 7: ...es Optional Accessories DMX M35AX Optional 2 Channel DMX Interface IF35 RCT Optional Remote Control Timer Output Fog Hose 2 5 m 8 long 13 cm 5 diameter Different lengths available Low Fog Output Front...

Страница 8: ...de L CO2 with Dip Tube or Siphon Use only carbon dioxide cylinder equipped with a dip siphon tube allowing the discharge of liquid CO2 Refrigerated Low pressure Liquid Carbone Dioxide L CO2 Container...

Страница 9: ...ng the start of the heating cycle which will last approximately 10 minutes When the temperature reaches a pre adjusted level called the READY level indicated by a green LED the HEAT yellow LED will tu...

Страница 10: ...ck panel of the generator 7 Unscrew the brass cap 8 Pour the MDG Low Fog Fluid until it reaches the inside bottom of the opening Avoid overfilling 9 Screw back the closure and make sure it is hand tig...

Страница 11: ...ocated on the back panel or unplug the generator Never install above people These Low Fog Generators must be installed on a stable and horizontal surface Do not operate at less than 2 meters 6 5 ft fr...

Страница 12: ...ments WARNING Only use High pressure Liquid Carbon Dioxide L CO2 with Dip Tube or Siphon If you have ordered the LP version only use low pressure refrigerated liquid Carbon Dioxide L CO2 Dewar contain...

Страница 13: ...emission on the remote Switch off the pressure switch on the main panel Close the valve of the high pressure Liquid CO2 bottle or refrigerated low pressure liquid L CO2 valve of the Dewar Power off th...

Страница 14: ...R BY TURNING OFF THE PRESSURE SWITCH LOCATED ON THE MAIN PANEL OF THE GENERATOR To fill the fluid reservoir Always turn off the low fog emission on the remote Switch off the pressure switch on the mai...

Страница 15: ...ize 0 5 4 5 microns CO2 running time High pressure version 23 kg 50 lb canister 17 minutes Low pressure version 180 L 48 US gallon canister DEWAR 120 minutes Warm up time maximum 8 10 minutes Fluid ty...

Страница 16: ...ICE FOG CompackTM User Guide120818 Rev B a 16 19 TECHNICAL DIMENSIONS...

Страница 17: ...DG Fog Generators Ltd will repair or replace it free of all charges except transportation costs This warranty applies only to the product itself and MDG Fog Generators Ltd declines responsibility for...

Страница 18: ...ICE FOG CompackTM User Guide120818 Rev B a 18 19 DECLARATION OF CONFORMITY...

Страница 19: ...ICE FOG CompackTM User Guide120818 Rev B a 19 19 NOTE...

Отзывы: