Atmosphere APS & Max APS Series
User Guide120815, Rev: A/a
5 / 11
SHUT
DOWN
PROCEDURE
A Generator must never be shut down while making Fog. To power off a Generator the
following sequence must be observed:
Always turn off the fog emission,
Wait a minimum of 1 minute for the purge cycle to complete, if possible avoid
purging at very low pressure which reduces the efficiency of the Automatic Purging
System
TM
. The recommended minimum purging pressure is 10 psi.
Power of the Fog Generator (by switching off the “MAIN POWER SWITCH” or by
removing the MAIN POWER.
The CO
2
or N
2
gases are used as a propellant when generating Fog / Haze. They are also
used for purging the heating module(s) when the APS
TM
cycle is initiated. Output
pressure can be adjusted by mean of the CO
2
or N
2
gas regulator. The ideal range for
MAX
TM
Series is 10 to 40 psi. and the H.O. / TOURING
TM
Version is 10 to 60 psi., for the
ATMOSPHERE
TM
Series it is 5 to 20 psi. and the H.O. / TOURING
TM
Version is 5 to 30 psi.
FILLING
OF
THE
FLUID
RESERVOIR
WARNING
Use only MDG Neutral Fog Fluid. Not doing so, will void the warranty and
may damage the generator
.
CAUTION
DISCONNECT UNIT BEFORE ADDING FOG FLUID.
To fill the fluid reservoir, unscrew the brass closure and pour the MDG Neutral Fog Fluid
until it reaches the inside bottom of the opening. Avoid overfilling, screw back the
closure and make sure it is tightened.