www.marketdirect.com.au
Ph: 1300 494 494
58
7
Fault of fuel
metering pump
1. Incorrect connection.
Check all the plugs for secure connection and
rectify if necessary.
2. Short circuit or open circuit
of lead.
Check whether there is short circuit or open
circuit of lead with multimeter. If yes, please fix it
or replace it.
3. Damage of fuel metering
pump.
Check fuel pump’s resistance between two leads.
If it is not between 15-25 ohms, pls replace it.
8
Fault of tempera-
ture sensor
1. Short circuit or open circuit
of lead.
Check whether there is short circuit or open
circuit of lead by multimeter. If yes, please fix it or
replace it.
2. Damage of temperature
sensor.
Check whether there is a damage of temperature
sensor. If yes, please replace it.
9
Ignition failure
1. No fuel in the container.
Check whether there is fuel or enough fuel in tank.
2. Fuel pipe blocked or broken. Check whether the pipe is blocked by impurity
and each connection is intact. if so, please repair
or replace it.
3. Fuel pipe blocked by
fuel condensation.
If there is fuel condensation, please use fuel which
is suitable for low temperature to replace
previous fuel.
4. Blockage in exhaust pipe.
Please clean the exhaust pipe if there is a block.
5. Fault of controller.
Replace the controller.
10
Flame failure
1. Not enough fuel in container.
Provide enough fuel.
2. Fault of ignition sensor.
Troubleshooting or replace it.
Содержание FORBES 13 2021
Страница 25: ...www marketdirect com au Ph 1300 494 494 21 Electrical Diagrams Switch Panel...
Страница 26: ...www marketdirect com au Ph 1300 494 494 22 Main Circuit...
Страница 43: ...www marketdirect com au Ph 1300 494 494 39...
Страница 48: ...www marketdirect com au Ph 1300 494 494 44 Hub Assembly...
Страница 49: ...www marketdirect com au Ph 1300 494 494 45 Trailing Arm Bushes...
Страница 70: ...www marketdirect com au Ph 1300 494 494 66 Trip Name Date Km Start Km Finish Cumulative Km...