Water Heater Trouble Shooting
Gas Operation
Water Supply
Symptom
Cause
Remedy
When switching on,
the heater does
not operate.
No 12 V DC supply voltage.
Check the power supply (operation voltage min. 10.5 V). Check
the Truma UltraRapid fuse (refer to maintenance “Fuses”).
When switching on,
the heater does not
operate and the red
lamp lights up after
approx. 30 secs.
– Cowl cover fitted.
– Air in the gas supply.
– No gas supply.
– Incorrect gas pressure.
Remove cowl cover and / or clear any obstruction.
Check gas valves and gas cylinder.
To unlock (and purge air), switch off the appliance, wait 5
minutes, and switch on again.
Heater operates
for a prolonged
time and then the
red lamp lights up.
Excess temperature
thermostat has responded.
Check water level, refill if required
(close drain valve).
To unlock, switch off the appliance, wait 5 minutes, and switch
on again.
Symptom
Cause
Remedy
Water drips from
the P&T safety
valve.
– Water pressure to high.
– Lime or dirt under the P&T
safety valve seat.
Check water pressure (max. 400 kPa), use a pressure reducer
when connected to central water supply.
Allow the appliance to cool and then slowly raise the test lever
(Fig. 2a – 4a) to flush the water system and attempt to force dirt
or foreign matter out of the P&T safety valve seat.
Replace P&T safety valve. This must be performed only by a
certified service technician.
When opening the
cold water tap, hot
water comes out.
– Hot water flows back through
the cold water supply.
- Fit a non-return valve in the cold water supply (refer to
installation instructions “Water connection”).
- Non return valve faulty
Water Pumps
The pump when switched on is activated by the release of pressure at the tap and will pump water continuously
until the tap is turned off and pressure restored. Should the pumps activate while the taps is turned off this could
indicate a leak and require investigation and rectification.
Grey Water Tank
Your grey water tank collects water from the internal ensuite and hand basin. Wastewater should only be dumped
at dedicated dump sites. Do not empty your grey water tank into the environment.
To empty your grey water, connect a suitable hose to the valve assembly, open tap and drain. Drainage will be faster
by removing the grey water flush cap.
Once empty, rinse and add tank freshener.
Содержание FORBES 13 2021
Страница 25: ...www marketdirect com au Ph 1300 494 494 21 Electrical Diagrams Switch Panel...
Страница 26: ...www marketdirect com au Ph 1300 494 494 22 Main Circuit...
Страница 43: ...www marketdirect com au Ph 1300 494 494 39...
Страница 48: ...www marketdirect com au Ph 1300 494 494 44 Hub Assembly...
Страница 49: ...www marketdirect com au Ph 1300 494 494 45 Trailing Arm Bushes...
Страница 70: ...www marketdirect com au Ph 1300 494 494 66 Trip Name Date Km Start Km Finish Cumulative Km...