28
FSD
CV
Description
S
A
Range
Note
130
A2 command allocation
2
see attachment 1
131
A2 dimming value
100
√
see attachment 2
132
A2 condition
0
√
see attachment 3
133
A2 special function
0
√
see attachment 4
134
A1 time for special function
5
√
1
–
255
time base (0,1s / value)
135
A2 servo speed
20
0
–
255
time base (1 ms / value)
136
A2 servo endposition right
200
0
–
255
value in degree
137
A2 servo endposition left
20
0
–
255
value in degree
138
A2 servo invers mode
1
0/1
servo will be in inverted mode if value = 1
139
A2 servo stop at end
1
0/1
servo stops moving at end levels if value = 1
140
A3 command allocation
3
see attachment 1
141
A3 dimming value
100
√
see attachment 2
142
A3 condition
0
√
see attachment 3
143
A3 special function
0
√
see attachment 4
144
A3 time for special function
5
√
1
–
255
time base (0,1s / value)
145
A3 servo speed
20
0
–
255
time base (1 ms / value)
146
A3 servo endposition right
200
0
–
255
value in degree
147
A3 servo endposition left
20
0
–
255
value in degree
148
A3 servo invers mode
1
0/1
servo will be in inverted mode if value = 1
149
A3 servo stop at end
1
0/1
servo stops moving at end levels if value = 1
150
A4 command allocation
4
see attachment 1
151
A4 dimming value
100
√
see attachment 2
152
A4 condition
0
√
see attachment 3
153
A4 special function
0
√
see attachment 4
154
A4 time for special function
5
√
1
–
255
time base (0,1s / value)
155
A4 servo speed
20
0
–
255
time base (1 ms / value)
156
A4 servo endposition right
200
0
–
255
value in degree
157
A4 servo endposition left
20
0
–
255
value in degree
158
A4 servo invers mode
1
0/1
servo will be in inverted mode if value = 1
159
A4 servo stop at end
1
0/1
servo stops moving at end levels if value = 1
160
A5 command allocation
5
see attachment 1
161
A5 dimming value
100
√
see attachment 2
162
A5 condition
0
√
see attachment 3
163
A5 special function
0
√
see attachment 4
164
A5 time for special function
5
√
1
–
255
time base (0,1s / value)
165
A5 servo speed
20
0
–
255
time base (1 ms / value)
166
A5 servo endposition right
200
0
–
255
value in degree
167
A5 servo endposition left
20
0
–
255
value in degree
168
A5 servo invers mode
1
0/1
servo will be in inverted mode if value = 1
169
A5 servo stop at end
1
0/1
servo stops moving at end levels if value = 1