MCZ VIVO 70 WOOD Скачать руководство пользователя страница 8

Chapter 2

 

INSTALLATION AND USE MANUAL 

page

 8  

 

Theoretical notions for installation 

Technical service – MCZ Group S.p.A. all rights reserved - Reproduction prohibited 

 

  

IMPORTANT! 

 

The fireplace stove must be installed and 

assembled by qualified personnel. 

 

The fireplace stove must be connected to a flue 

pipe or other vertical smoke stack that can 

discharge smoke at the highest point of the 

house.  

 

The closed fireplace must be connected to a flue 

pipe or internal or external vertical duct, in 

accordance with the applicable standards in force. 

 

Smoke is generated from burning wood and, 

therefore, may dirty adjacent or nearby walls. 

 

Before positioning the fireplace stove, you must 

make a hole for the intake of external air. 

 

2.3.  

CONNECTION TO THE EXTERNAL AIR INTAKE 

The room where the stove is installed must have at least as much air as 

requested by normal combustion of the equipment and by room 

ventilation. This may take place through permanent apertures in the 

room walls that lead directly outdoors or ventilated rooms according to 

UNI 10683 REV. 
For this purpose, drill a hole with minimum 360 cm² free section near 

the fireplace stove (22 cm diameter or a 20x18cm rectangle), protected 

by an indoor and outdoor grille. 
The air intake must also: 

 

directly communicate with the installation room 

 

be protected by a grill, made of metallic anti-insect mesh or a 

suitable protection as long as it does not reduce the minimum 

section. 

 

be installed so as to avoid obstruction 

 

for ducts, up to 3.5 linear metres, increase the section by about 

5% while increased by 15% for larger measurements. 

 

 

Remember that the ventilation grills always have a cm

2

 

useful section on one side. When selecting the grill and hole 

dimension, make sure the useful grill section is greater than 

or equal to the section required by MCZ for product 

operations. 

  

IMPORTANT! 
Air flow may also be obtained from a room adjacent 

to the installation room as long as this flow is free 

through permanent apertures that directly 

communicate with the outdoors; avoid air outlets 

connecting with heating units, garages, kitchens or 

bathrooms. 

 

Содержание VIVO 70 WOOD

Страница 1: ...8901156000 MANUALE DI USO ED INSTALLAZIONE EN...

Страница 2: ...RT AIR VF 16 4 3 EXTERNAL AND INTERNAL AIR INTAKE 17 4 3 1 Combustion air inlet 17 4 3 2 Air inlet for natural ventilation 17 4 3 3 Air inlet for forced ventilation 17 4 4 POSITIONING 18 4 5 ADJUSTMEN...

Страница 3: ...ON 34 6 1 PRE LIGHTING WARNINGS 34 6 2 OPERATING TEST 34 6 2 1 Phases for first test lighting 35 6 3 CHOICE OF FUEL 35 6 4 FIRST LIGHTING 36 6 5 LOADING THE FUEL 37 6 6 CONTROL OF COMBUSTION 38 6 7 SM...

Страница 4: ...ut prior notice Reproduction even partial of this manual without the Manufacturer s authorisation is prohibited Manual preservation Please take care of this manual and keep it in a place that can be q...

Страница 5: ...on original spare parts may be hazardous to the user and releases MCZ from any civil or penal liability Parts of the surfaces of the fireplace stove are very hot door handle glass Therefore avoid dire...

Страница 6: ...y for any damage which may be caused directly or indirectly by persons animals or things as a result of the failure to observe all the provisions set forth in the instruction booklet especially those...

Страница 7: ...with outdoor air vents and not bedrooms or bathrooms or rooms where fire hazards do not exist such as garages wood sheds flammable material warehouses strictly observing the provisions of current regu...

Страница 8: ...apertures in the room walls that lead directly outdoors or ventilated rooms according to UNI 10683 REV For this purpose drill a hole with minimum 360 cm free section near the fireplace stove 22 cm dia...

Страница 9: ...too short to avoid smoke leakage If metal connecting pipes are used they must be insulated with suitable material such as ceramic fibre matting to avoid deterioration of the masonry and of the decorat...

Страница 10: ...irtight door IMPORTANT In the event of doubt on your chimney flue operations or that its dimensions are different from those recommended we highly suggest an authorised MCZ technician inspect and meas...

Страница 11: ...lt to prevent rain snow and any foreign objects from getting into the flue pipe They must be installed to guarantee adequate smoke dispersion and out of the reflux area where negative pressure forms F...

Страница 12: ...ssembly Technical service MCZ Group S p A all rights reserved Reproduction prohibited 3 DIMENSIONS AND TECHNICAL SPECIFICATIONS 3 1 Dimensions VIVO 70 WOOD 717 D150 D200 D150 15 670 8 5 620 539 15 8 5...

Страница 13: ...Installation and assembly Technical service MCZ Group S p A all rights reserved Reproduction prohibited 3 2 Dimensions VIVO 90 WOOD D150 D200 D150 432 432 182 170 202 864 11 5 11 5 458 23 5 15 45 12 4...

Страница 14: ...5x25 cm 25 Between 5 and 7 m 22x22 cm 22 Over 7 m 20x20 cm 20 Note Intermittent combustion unit Appliance suitable for installation in a shared flue Data may vary according to the fuel used Technical...

Страница 15: ...ARATION AND UNPACKING Open the packaging remove the stove unit from the pallet and position it in the chosen location taking care that its position complies with the above instructions The fireplace s...

Страница 16: ...n the back of the stove unit figure 1 If it is not possible to connect directly to the air intake at least connect the flange to the outside of the cladding This operation is necessary to ensure prope...

Страница 17: ...of the duct with the flange F 100 5 turn the duct F so that the flange 100 faces downwards 6 Perform the steps in points 1 2 3 4 in reverse order In the absence of this direct connection B it is obli...

Страница 18: ...hem Do not for any reason obstruct the air intakes if the fireplace stove or ventilation kit is in operation 4 4 POSITIONING The VIVO fireplace stove can be placed in a corner or along a wall It can b...

Страница 19: ...USE MANUAL page 19 Installation and assembly Technical service MCZ Group S p A all rights reserved Reproduction prohibited 530 510 870 500 10 960 610 510 705 500 790 10 Vivo 90 Wood wall hole size Vi...

Страница 20: ...ed by fitting one into another Figure 9 Any increase in the section of the connecting pipe must start immediately above the hood of the fireplace and not along the flue pipe section When installation...

Страница 21: ...i dalla mancata osservanza di questa avvertenza For proper operation of room ventilation remember that In the lower part of the cladding an opening for the entry of convective air must be provided tha...

Страница 22: ...nation 1 2 4 3 5 1 Structure of basic natural ventilation outlet 2 pieces 2 Fastening bracket group 2 pieces 3 Hose 150 L 1 5 m 2 pieces 4 Flange 150 2 pieces 5 Hose clamp D 60 170 4 pcs 5 1 2 Compone...

Страница 23: ...natural ventilation kit with and without illumination A C D B E A One direction air outlet without illumination includes container for dehumidification B One direction air outlet with illumination in...

Страница 24: ...S p A all rights reserved Reproduction prohibited 5 2 2 Air outlets for forced ventilation kit B C D A A One direction air outlet includes container without illumination B One direction air outlet in...

Страница 25: ...uts provided fig 2 5 connect the hose a previously fastened to the fireplace hose to the connection located on the structure of the air outlet e 6 tighten the hose a on the connection e with the provi...

Страница 26: ...t is facing the front of the structure fig 6 Fasten the light using the two brackets c with the screws b and bolts d provided Once you have inserted the light a make the electrical connections In the...

Страница 27: ...are resistant to high temperatures such as those used in kitchen ovens Cleaning glass light fixture of the air outlet 1 Open the door that contains the dehumidification container 2 Remove the contain...

Страница 28: ...ed with 6 double terminals for the connection of 1 Line 1 2 LINEA 2 Fan 1 3 4 VENTIL 3 Fan 2 5 6 VENTIL 4 Light 7 8 AUX 5 Switch for door opening 9 10 PORT 6 Probe 11 12 SONDA 5 4 2 Positioning of the...

Страница 29: ...to 10 speed steps 0 V1 V9 V10 MANUAL AUTOMATIC mode is set using button 4 5 5 1 On off The control unit is turned on and off by turning knob 3 On status is indicated by LED 1 5 5 2 Operation Activati...

Страница 30: ...of the structure If the safety function trips frequently contact the technical service department of MCZ 5 5 4 Light on if present Press button 5 to turn the light on or off The LED 5a indicates the...

Страница 31: ...y the installer PROBE INSTALLATION Insert the plastic piece C in D and screw in B without forcing it On the threaded part of piece D insert washer E The group thus formed A1 must be inserted on the ri...

Страница 32: ...4 and 5 6 Connect the probe 11 12 see paragraph 5 6 For air outlet with light connect the power cord to the control unit on the terminals 7 8 For air outlets with a light for natural ventilation make...

Страница 33: ...t fixture has a light bulb disconnect the power cables when extracting the flange It is now sufficient to turn the fan with respect to the duct to allow passage without damaging the piece IMPORTANT TH...

Страница 34: ...ing the fireplace stove is subject to expansion and contraction therefore you may hear slight creaking noises This phenomenon is absolutely normal the structure being made of sheet steel and must not...

Страница 35: ...used with caution to avoid overheating which could damage the stove It is advisable to use fuels such as poplar pine lime tree or chestnut which have low calorific power since they are soft wood and a...

Страница 36: ...the door open to the first stage When the twigs are burning the door can be closed Only once the flame is burning well presence of a bed of coals and full combustion place the air adjustment between...

Страница 37: ...rts During normal use always keep the fire door completely closed since intermediate positions cause abnormal combustions forge effect rapid consumption of wood and a drastic reduction in the heating...

Страница 38: ...the combustion chamber is hot enough The use of damp or treated wood emits a higher quantity of smoke than normal that can dirty glass faster Also the low performance of the flue pipe can jeopardise...

Страница 39: ...n the screws on the sides Loosen the frame This operation is possible to replace the frame provided with the optional one of 50 mm 6 9 EMERGENCY SITUATIONS If for any reason the stove fire needs to be...

Страница 40: ...kept outdoors with great care and not placed in a waste container Leave them to cool down in the open air in a metal container 7 1 3 Cleaning the refractory material walls ALUTEC They do not require a...

Страница 41: ...DEALT WITH BY SPECIALIZED TECHNICIAN 7 2 1 Cleaning flue pipe Mechanical cleaning of the flue pipe is recommended at least once a year Excessive deposits of unburnt solid material can cause problems...

Страница 42: ...MCZ GROUP S p A Via La Croce 8 33074 Vigonovo di Fontanafredda PN ITALY Telephone 39 0434 599599 PBX Fax 39 0434 599598 Internet www mcz it e mail mcz mcz it 8901155700 Rev 0 12 2011...

Отзывы: