Chapter 4
INSTALLATION AND USE MANUAL
page
21
Installation and assembly
Technical service – MCZ Group S.p.A. all rights reserved - Reproduction prohibited
Dry install the fire bed of the
cladding, leaving an aperture of
1 cm
between the fireplace stove and the fire bed to provide insulation.
4.8.
INSULATING A WOODEN BEAM
The wood beam must be protected with adequate insulation
from heated parts to prevent the risk of fire or damage of the
cladding.
(figure 10)
4.9.
INSULATION OF FIREPLACE STOVE
The fireplace stove must also always be separated from nearby
walls and ceilings.
If necessary, use
insulating materials
to insulate the walls that are in
contact with the unit if they may be damaged or catch fire (walls made
of wood, plasterboard, etc.).
(figure 11)
Measurements for insulation are shown in chap 4.4
4.9.1.
Hood ventilation nozzles.
You
must
install MCZ ventilation nozzles, or nozzles
that ensure the same operation and the same air
passage cross section (see MCZ accessories).
MCZ non risponde di eventuali danni alla struttura o
alla componentistica elettrica causati dalla mancata
osservanza di questa avvertenza.
For proper operation of room ventilation remember that:
In the lower part of the cladding, an opening for the entry of
convective air must be provided that is not smaller than 400
cm
2
In the upper part it is necessary to provide a vent opening (in
addition to the ducted air outlets) of at least 230 cm
2
to release
into the room the residual heat that accumulates inside the
cladding. With the COMFORT AIR kit, however, this outlet is
not necessary, because the heat in the cladding is indirectly
drawn in by the fans.
Besides ensuring perfect product operation, this action makes it
possible to recover part of the heat from the structure, which would be
wasted if it were left inside the cladding.
For better understanding of the number, size and function of the
ventilation nozzles to be installed on the cladding, the following are
some possible installation configurations with the relative nozzles.
1a)
Grille for convection air outlet
1b)
Grille for intake of convection air
Grilles
1a
and
1b
are essential for releasing the heat that
builds up in the hood. They
must
be installed, regardless of
the type of installation or cladding to be realized.
Figure 11
– Insulation of unit from walls and
from cladding
INSULATION
1a
1b