Chapter 4
INSTALLATION AND USE MANUAL
page
46
Operation
Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
If the reduction motor stops, the stove continues to function until
it has cooled down to the minimum level.
•
TEMPORARY POWER OUTAGE
If there is a power outage during operation, when the power
comes back on the stove will go into cooling mode and then it will
come back on automatically.
•
FAILURE TO LIGHT
If during ignition no flame develops, the stove will go into alarm
condition.
TAMPERING WITH THE SAFETY DEVICES IS
PROHIBITED
It is only after eliminating the cause which gave rise to the
intervention of the safety system, that it is possible to relight
the stove and thus reset the automatic operation of the
sensor. To understand which anomaly has occurred, consult
this manual at paragraph 4.17 which explains what to do
based on the alarm message the stove displays.
ATTENTION
If the stove is not used as described in this instruction booklet,
the manufacturer refuses to accept any responsibility for
damage to persons and property that may arise. The
manufacturer furthermore refuses to accept responsibility for
damage to persons and property arising from the failure to
observe all the rules contained in the manual and in particular:
•
Failure when carrying out works of maintenance,
cleaning and repair to adopt all necessary measures and
precautions
•
Tampering with the safety devices.
•
Removing the safety devices.
•
Failure to connect the stove to an efficient system for the
discharge of smoke.
•
Failure to check in advance that the room where the
stove is to be installed is adequately ventilated.
4.19.
ALARM SIGNALLING
If there is an operating anomaly, the stove goes into alarm shutdown
mode and informs the user of the type of problem that has occurred via
a 3-figure code displayed on the rear emergency panel.
The alarm is permanently signalled by the corresponding 3-figure code,
by a flashing red light on the emergency panel, and, for the first ten
minutes of the alarm, by a periodic acoustic signal, which can be
interrupted by turning the unit off with the remote control. To exit
alarm conditions and restore its normal operation, read the instructions
in the next two paragraphs.
The following table summarizes the possible alarms which the stove
may signal and corresponding code which appears on the emergency
panel.
Содержание Powerbox Compact-Link
Страница 1: ...INSTALLATION AND USE MANUAL...