Chapter 3
INSTALLATION AND USE MANUAL
page
17
Installation and fitting
Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited
The unit can be installed at the desired level, creating a structure of the
opportune height. This support must be constructed in inflammable
material.
MCZ declines any responsibility for possible damages
to persons or things if the aforementioned warnings
are not respected.
3.4.
REMOVAL OF COMPENSATION FRAME
To avoid damage to the border frame (
C
) located around the fire door,
it is recommended to remove it before mounting the Powerbox to the
base (
E
) and to put it in a safe place. For removal, see
chap. 3.13
3.5.
INSTALLATION OF PELLET LOADING CHUTE
(LINK)
Before positioning the unit, you will need to decide on which side the
chute for fuel loading will be installed.
The Powerbox Link is provided with two straps, the connecting tube
and the chute with a small door.
The chute can be assembled on the right side, the left side or on the
front. The connecting tube is one meter long.
It is mandatory to shorten the connecting tube in
accordance with its position (side or front) in a way
that results in the tube being firmly extended. This
operation is necessary to facilitate pellet descent.
Before assembling the cladding, execute a test by
loading the combustible fuel to make sure that the
pellets descend correctly towards the hopper.
B
B
C
C
D
E
Mounting to the base