6
1-WARNINGS AND WARRANTY CONDITIONS
INFORMATION:
•
Please contact the retailer or qualified personnel for any information, problem or malfunction.
•
Only use the fuel specified by the manufacturer.
•
When the product is switched on for the first time, it is normal for it to emit smoke due to the paint heating up for the first time.
Therefore make sure the room it is installed in is well-ventilated.
•
Periodically check and empty the inspectionable parts of the smoke duct (e.g. Tee fitting caps)
•
Have the smoke outlet system periodically checked and cleaned
•
The product is not a cooking appliance.
•
Always keep the cover of the fuel hopper closed.
•
Store this installation and user manual with care as it must accompany the product for the duration of its useful life. If the product is
sold or transferred to another user, always ensure the manual is also handed over.
INTENDED USE
The product only works with wood pellets and must be installed inside a room.
PRODUCT PERFORMANCE CHECKS.
All our products undergo ITT TESTS carried out by a notified third party laboratory (system 3) and in accordance with Regulation (EU)
number 305/2011 “Construction products”, according to standard EN 14785:2006 for household appliances and “Machinery Directive” EN
303-5 for boilers.
In the case of tests for any market surveillance or inspections by third parties, please consider the following warnings:
•
To reach the declared performance levels, the product must perform an operating cycle of at least 15-20 hours beforehand.
•
Set the average draught of the combustion fumes as specified in the “technical product features” table
•
The type of pellets used must comply with the current EN ISO 17225-2 class A1 regulation. Fir pellets are usually used for certification.
•
The amount of thermal energy can vary according to the length and calorific value of the fuel. This may require some adjustments
(accessed from the user menu) to comply with the hourly consumption specified in the “technical product features” table. Using class
A1 pellets guarantees a calorific value that is likely to be close to that used in the product certification; the size of the pellet grains can
significantly affect hourly fuel loading and consequently performance; it is therefore suggested to use pellets with a 6 mm diameter
and an average length of around 24 mm (avoid pellets that are too long or excessively crushed).
•
With wood-burning appliances, the fuel must comply with the current EN ISO 17225-5 class A1 regulation. Check the correct moisture
of the fuel, as it must be within the range of 12 - 20% (it is best if the moisture is close to 12%, as is normally used in certification). As
the fuel moisture increases, different combustion air settings are required, which are implemented from the combustion air register,
thereby modifying the mixture of primary and secondary air
•
It is important to check the operation of devices that can affect performance (for example air fans or electric safety devices) in case
of damage due to handling.
•
Nominal performance has been obtained by setting the maximum flame power and room ventilation in
manual
mode.
Performance at reduced power was achieved at minimum flame and ventilation power (P1 and V1) in manual mode.
The other conditions correspond to intermediate ventilation and power.
•
If a “verification” mode is provided in the menu, set this function during the readings to ensure that no temperature modulation
occurs due to an incorrect setting of the operating parameters.
•
Lastly, strictly comply with the sampling points specified in the regulations in terms of emissions as well as temperature