61
9-ELECTRICAL CONNECTION
Technical Dept. - All rights reserved - Reproduction prohibited
ELECTRICAL CONNECTION
First connect the power cable to the back of the stove and then to a wall socket.
It is recommended to disconnect the power cable when the stove is not used.
The cable must never come into contact with the smoke exhaust pipe or any other part of the stove.
STOVE POWER SUPPLY
Connect the power cable to the back of the stove and then to a wall socket. The stove is then powered.
There is a fuse box also in the switch block next to the power socket. Open this compartment by simply lifting the cover, using a screwdriver
as a lever from inside the power outlet compartment. Inside there are two fuses (5x20 mm T delayed / 3.15 A 250 V), which may need
to be replaced if the stove is not powered (e.g. the control panel display does not light up) - operation to be implemented by a qualified
technician.
ATTENTION!
All cleaning and / or replacement of parts must be carried out with the power plug disconnected.
Disconnect the product from the 230V power supply before performing any maintenance operations.
If the cable is damaged, replace it.
ELECTRICAL STOVE CONNECTION
STOVE POWER SUPPLY
FUSE BOX