MC3419 3-Axis Accelerometer
EV3419A Quick Start Guide and Demo
mCube Proprietary.
APS-045-0033v1.0
16 / 20
© 2020 mCube Inc. All rights reserved.
6 SCHEMATICS
Above is a schematic on EV3419A. This is the factory preset when receiving the part.
For other options, please refer to the following table:
Interface
R1
R2
R3
SPI or I2C 0x4C (
Factory default
)
100KΩ
DNI
1
10KΩ
SPI or I2C 0x6C
100KΩ
10KΩ
DNI
R4, R5:
Install ~4.7K
Ω as the I2C pull-ups if using I2C mode and there is no I2C pull-ups
installed. (DNI by default)
Note: It is recommended not to install more than one pull-ups per I2C bus.
R6:
Install ~4.7K
Ω
pull-up resistor if setting the sensor interrupt pin to open-drain. (DNI by default)
R7:
Sensor’s driving current can be measured by putting an ammeter in place of R7.
The physical location of the resistor is in the diagram in Section 8.
1
DNI: Do Not Install