(B) Outdoor Unit
As condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to
achieve maximum cooling capacity, the location selected for outdoor unit should fulfill the following
requirements :
•
Install the condensing (outdoor) unit in away such that hot air distributed by the outdoor condensing
unit cannot be drawn in again (as in the case of short circuit of hot discharge air). Allow sufficient
space for maintenance around the unit.
•
Ensure that there is no obstruction of air flow into or out of the unit. Remove obstacles which block air
intake or discharge.
•
The location must be well ventilated, so that the unit can draw in and distribute plenty of air thus
lowering the condensing temperature.
•
A place capable of bearing the weight of the outdoor unit and isolating noise and vibration.
•
A place protected from direct sunlight. Otherwise use an awning for protection, if necessary.
•
The location must not be susceptible to dust or oil mist.
Installation Clearance
•
Outdoor units must be installed such that there is no short circuit of the hot discharge air or
obstruction to smooth air flow. Select the coolest possible place where intake air should not be hotter
than the outside temperature.
ALL MODELS
A
B
C
D
Minimum Distance
300mm
1000mm
300mm
500mm
CAUTION : If the condensing unit is operated in an atmosphere containing oils(including machine
oils), salt(coastal area), sulphide gas(near hot spring, oil refinery plant), such
substances may lead to failure of the unit.
74
Содержание MWM 007F
Страница 37: ...MWM 007F FR NC Curves MWM 010F FR NC Curves 35...
Страница 38: ...36 MWM 015F FR NC Curves MWM 020F FR NC Curves...
Страница 39: ...MWM 025F FR NC Curves MWM 030F 030FR NC CURVES 37...
Страница 43: ...Indoor Unit Model MWM 010F 010FR 015F 015FR Outdoor Unit Model MLC 010C 010CR 015C 015CR 41...
Страница 45: ...43 Model MLC 030B Model MLC M4LC 030C...
Страница 46: ...Heatpump Models Model M4LC 007BR 010BR MLC 010CR Model M4LC 015BR 44...
Страница 47: ...Model MLC 015CR Model MLC M4LC 020BR 45...
Страница 48: ...Model MLC M4LC 025BR MLC 030BR Model MLC M4LC 030CR 46...
Страница 52: ...Outdoor Unit Model MLC 030B Indoor Unit Model MWM 030F D2 0 I C 50 1 PHASE 220 240V 50Hz...
Страница 53: ...Indoor Unit Model MWM 030F D2 01 C Outdoor Unit Model MLC M4LC 030C 51...
Страница 54: ...Indoor Unit Model MWM 030F D2 01 C Outdoor Unit Model MLC M4LC 030C 52...
Страница 55: ...Indoor Unit Model MWM 015F D2 0 I C Outdoor Unit Model MLC 015C 1 PHASE 220 240V 50 Hz 53...
Страница 56: ...Indoor Unit Model MWM 010F D2 0 I C 1 PHASE 220 240V 50 Hz Outdoor Unit Model MLC 010C 54...
Страница 60: ...Indoor Unit Model MWM 030FR U1 4 1 C Outdoor Unit Model MLC M4LC 030CR 58...
Страница 61: ...59 Indoor Unit Model MWM 030FR U1 4 1 C Outdoor Unit Model MLC M4LC 030CR...
Страница 62: ...Indoor Unit Model MWM 030FR U1 4 I C Outdoor Unit Model MLC 30BR 1 PHASE 220 240V 50HZ 60...
Страница 63: ...Indoor Unit Model MWM 010FR U1 4 I C Outdoor Unit Model MLC 010CR 61...
Страница 64: ...Indoor Unit Model MWM 015FR U1 4 I C 1 PHASE 220 240V 50 Hz Outdoor Unit Model MLC 015CR 62...
Страница 74: ...Installa Installa Installa Installa Installation tion tion tion tion Installation Diagram 72...
Страница 108: ...2005 McQuay International 1 800 432 1342 www mcquay com...