OM 750
Page 3 of 32
Index of
Meaning of Abreviations
Abreviations
AHED
Auxiliary Heat End Differential
AHSD
Auxiliary Heat Start Differential
ASCII
American Standard Code for Information Interchange
ASHRAE
American Society of Heating, Refrigerating,
and Air Conditioning Engineers, Inc
CCLO
Compressor Cooling Lockout Setpoint
CO2S
CO
2
Setpoint
CW
Chilled Water
CWVP
Chilled Water Valve Position
DA
Discharge Air
DAHL
Discharge Air High Limit
DAT
Discharge Air Temp
DATS
Discharge Air Temp Setpoint
DCV
Demand Controlled Ventilation
ECD
Economizer Compare Differential
EED
Economizer Enthalpy Differential
EES
Economizer Enthalpy Setpoint
EHS
Emergency Heat Setpoint
EOAD
Exhaust Outdoor Air Damper
EOAT
Outdoor Air Temperature Output
EOC
End-of-Cycle
EOCS
End-of-Cycle Low OAT Setpoint
EORH
Outdoor Air Humidity Output
ERH
Space Humidity Output
ETD
Economizer Temperature Differential
ETS
Economizer Temperature Setpoint
EWIT
Source (Water-in) Temperature
FBDP
Face and Bypass Damper Position
FCC
Federal Communications Commission
F & BP
Face & Bypass
HVACR
Heating, Ventilating, Air Conditioning, Refrigerating
HW
Hot Water
IA
Indoor Air
IAF
Indoor Air Fan
IAT
Indoor Air Temperature
UVC Input and Output Table .............................................. 27
Diagnostics and Service .................................................. 27
Alarm and Fault Monitoring ......................................................... 27
Space Temp Sensor Failure ................................................... 28
DX Pressure Fault .................................................................. 28
Compressor Envelope Fault ................................................... 28
Discharge Air DX Cooling Low Limit Indication ..................... 28
Condensate Overflow Indication (optional) ............................ 28
Space Coil DX Temp Sensor Failure ....................................... 28
Outdoor Temp Sensor Failure ................................................ 28
Table 1. Abbreviations
Index of
Meaning of Abreviations
Abreviations
LED
Light Emitting Diode
LUI
Local User Interface
MCLL
Mechanical Cooling Low Limit
NEC
National Electrical Code
OA
Outdoor Air
OAD
Outdoor Air Damper
OADE
Energize Exhaust Fan OAD Setpoint
OADH
OAD Min Position High-Speed Setpoint
OADL
OAD Min Position Low-Speed Setpoint
OADM
OAD Min Position Medium-Speed Setpoint
OADP
Outdoor Air Damper Position
OALS
Outside Air Lockout Position
OAMX
OAD Maximum Position Setpoint
OAT
Outdoor Air Temperature
OCS
Occupied Cooling Setpoint
OHS
Occupied Heating Setpoint
PI
Proportional Integral
PPM
Parts Per Million
RH
Relative Humidity
RHS
Space Humidity Setpoint
RO
Read Only
RW
Read Write
SCS
Standby Cooling Setpoint
SHS
Standby Heating Setpoint
TXV
Thermal eXpansion Value
UCS
Unoccupied Cooling Setpoint
UHS
Unoccupied Heating Setpoint
UV
Unit Ventilator
UVC
Unit Ventilator Controller
UVCM
UVC (Heat/Cool) Mode Output
UVCS
UVC State Output
VALP
Wet Heat Valve Position
VCLL
Ventilation Cooling Low Limit
WH
Wet Heat
WITD
Source (Water-in) Temperature Differential
Discharge Air Temp Sensor Failure ........................................ 28
Outdoor Coil DX Temp Sensor Failure ................................... 28
Space Humidity Sensor Failure (optional) ............................. 28
Outdoor Humidity Sensor Failure (optional) .......................... 28
Space CO
2
Sensor Failure (optional) ...................................... 29
Change Filter Indication ......................................................... 29
Troubleshooting Temperature Sensors ........................................ 29
Troubleshooting Humidity Sensors ............................................. 29
Troubleshooting Carbon Dioxide (CO
2
) Sensors .......................... 29
UVC Configuration Parameters .......................................... 30