Nomenclature System
M
DB
150
B
2
BRAND STATIC BLOWER 150,000 BTU/HR
GENERATION
NUMBER OF
REFRIGERANT
CIRCUIT
Features
Easy Maintenance
The simple design concept has maintenance and servicing in mind. Access to the internal part of the unit can be from
either side of the unit by loosening a few screws.
Only for model MDB 075B and 100B
with additional servicing panel from bottom
Flexibility In Installation
MDB 075B - MDB 150B models come with standard horizontal air discharge whereas MDB 200B - ADB 750B models
come with standard vertical air discharge. However, the range from MDB 125B - MDB 750B are designed to cater for
either horizontal or vertical air discharge application.
Versatility
Multiple rooms can be cooled together at the same time by using just one unit of fan coil unit.
Fresh Air For Healthy Living
Fresh air can be introduced into the building through the design of fresh air intakes. This will help to improve the indoor
air quality.
Superior Air Distribution For Comfortable Living
The conditioned air can be effectively distributed to every corner of the room through the ducting and this ensure a more
pleasant environment for comfort living.
Flexibility Of Air Supply
McQuay MDB series using belt driven fan such as that the air volume and static required can be adjusted according to
the requirement. This flexibility allow for wider application.
Содержание MDB075B
Страница 1: ...MDB 2004 Ducted Split Systems Models MDB 075 750B MDB 125 150C MDB 075 500BR MDB 125CR...
Страница 38: ...37 Blower Performance Curves MDB 075B BLOWER PERFORMANCE CURVE...
Страница 39: ...38 MDB 100B BLOWER PERFORMANCE CURVE...
Страница 40: ...39 MDB 125B BLOWER PERFORMANCE CURVE...
Страница 41: ...40 MDB 125C BLOWER PERFORMANCE CURVE...
Страница 42: ...41 MDB 150B BLOWER PERFORMANCE CURVE...
Страница 43: ...42 MDB 150C BLOWER PERFORMANCE CURVE...
Страница 44: ...43 MDB 200B BLOWER PERFORMANCE CURVE...
Страница 45: ...44 MDB 250B BLOWER PERFORMANCE CURVE...
Страница 46: ...45 MDB 300B BLOWER PERFORMANCE CURVE L s...
Страница 47: ...46 MDB 350B BLOWER PERFORMANCE CURVE...
Страница 48: ...47 MDB 400B BLOWER PERFORMANCE CURVE...
Страница 49: ...48 MDB 450B BLOWER PERFORMANCE CURVE...
Страница 50: ...49 MDB 500B BLOWER PERFORMANCE CURVE...
Страница 51: ...50 MDB 600B BLOWER PERFORMANCE CURVE...
Страница 52: ...51 MDB 750B BLOWER PERFORMANCE CURVE...
Страница 53: ...52 Outlines And Dimensions Indoor MODEL MDB 075 100 B BR MODEL MDB 125C HORIZONTAL AIR DISCHARGE ONLY...
Страница 60: ...59 MODEL MMC 075C CR MODEL MMC 100C...
Страница 61: ...60 MODEL MMC 125BR 150C STANDARD VERTICAL DISCHARGE NON CONVERTIBLE...
Страница 69: ...68 MODEL INDOOR MDB 400B4 MDB 500B4 WITH SEQUENTIAL CONTROLLER OUTDOOR MMC 100B x 4 MMC 125B x 4...
Страница 70: ...69 MODEL INDOOR MDB 600B4 WITH SEQUENTIAL CONTROLLER OUTDOOR MMC 150C x 4...
Страница 71: ...70 MODEL INDOOR MDB 750B5 WITH MAGNETIC CONTACTOR OUTDOOR MMC 150C x 5 INDOOR AUXILLARY C1 C1...
Страница 72: ...71 Wiring Diagrams Heatpump INDOOR EXPORT MODEL MDB 075 100BR C3 0B MODEL MDB 125CR EXPORT...
Страница 73: ...72 MODEL MDB 150 200 250 BR2 EXPORT MODEL MDB 300 350 BR3 EXPORT...
Страница 74: ...73 MODEL MDB 400 500 BR4 EXPORT...
Страница 84: ...83 Refrigerant Circuit Diagram MODEL MMC 075C 100C...
Страница 85: ...84 MODEL MMC 075B 100B 125B 150C...
Страница 86: ...85 MODEL MMC 075CR WITH CAPILLARY TUBE EXPANSION SPECIFICATION...
Страница 87: ...86 MODEL MMC 100BR 125BR WITH CAPILLARY TUBE EXPANSION SPECIFICATION...
Страница 88: ...87 MODEL MMC 075CR WITH THERMAL EXPANSION VALVE SPECIFICATION...
Страница 89: ...88 MODEL MMC 100BR 125BR WITH THERMAL EXPANSION VALVE SPECIFICATION...
Страница 101: ...100 SEQUENTIAL CONTROLLER BLOCK DIAGRAM...
Страница 163: ...2004 McQuay International 1 800 432 1342 www mcquay com ISO 9002 REGISTERED...