Main Features

General

The  new  MCW-D  FCUs  are  specifically  designed  to  satisfy  high  cooling  capacity  application  requirement.  They 

represent one of the most cost effective solutions to provide a comfortable environment for both commercial and 

residential  applications. Their  quiet  operation,  compact  dimensions  and  particularly  low  height,  make  units  ideal 

for  ceiling  concealed  installation  even  in  buildings  with  narrow  ceiling  spaces.  Units  are  standard  supplied  with 

soundproofed suction plenum and air filter. Centrifugal fans, with forward-curved blades, are statically and dynamically 

balanced and driven by single-phase motors with three speeds.They feature elegant design, advanced structure, 

high efficiency, low noise, convenient installation and low maintenance. They are widely used in houses, shopping 

malls, hospitals and office etc.

Higher Cooling Capacity in High Delta T Application

These units are particularly suitable for high External Static Pressure and high Delta T(chilled water temperature 

difference) applications. They can delivery more cooling capacity in high Delta T conditions with the specially designed 

fans & motors, coils and excellent combination of them.

Low Chilled Water Pressure Drop

In  order  to  meet  even  the  most  demanding  customer  requirements,  the  new  FCUs  adopt  the  most  reasonable 

and optimization water circuit design and utilize the national level thermal test room to guarantee both the perfect 

performance and a low chilled water pressure drop. 

Extra High Air Flow Volume at High ESP

These units can supply more air flow at high ESP. 10 models of MCW-D cover an air flow range from 340 to 2380CMH 

at medium speed with ESP of 75Pa in wet coil condition.

Air Filter

All units can provide up to one-inch thick washable filters. Filters are held by a removable metal strip and can be 

easily pulled out from the bottom for cleaning or replacement.

High Efficiency Heat Exchanger

A boundary layer film of air adhering to the fin surface will insulate the fin surface and severely reduces the heat 

exchange efficiency. McQuay slit fin design eliminates this boundary layer of air and creates continuous turbulence 

for best heat exchange efficiency.

Flexibility

Units are available with left or right hand water connections, which can be easily switched in the field by changing the 

positions of the fan-motor assembly and the supply air flange assembly if required.

Compact Design

The low height design makes this fan coil unit series ideally suited for the tight ceiling concealed installation

Low Noise Design

Enlarged  fan  wheels  design  allows  lower  fan  RPM  selection  for  the  same  external  static  pressure  and  airflow 

requirement. Thereby noise level is significantly reduced.

Содержание MCW1000D

Страница 1: ...ING CONCEALED Chilled Water Fan Coil Unit Models MCW200D MCW800D MCW300D MCW900D MCW400D MCW1000D MCW500D MCW1200D MCW600D MCW1400D Technical Manual Engineered for flexibility and performance TM MCWD...

Страница 2: ...in illustrations cover the general appearance of McQuay International products at the time of publication We reserve the right to change design and construction specifications at any time without noti...

Страница 3: ...ler L Extended Drain Pan Controller M Extended Drain Pan 2 Way Valve Controller N Extended Drain Pan 3 Way Valve Controller O Standard Drain Pan 2 Way Valve Controller P Standard Drain Pan 3 Way Valve...

Страница 4: ...customer requirements the new FCUs adopt the most reasonable and optimization water circuit design and utilize the national level thermal test room to guarantee both the perfect performance and a low...

Страница 5: ...75 75 75 75 75 75 in wg 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 RATED POWER INPUT W 74 98 107 123 167 268 275 304 501 555 SOUND PRESSURE LEVEL DB A 42 9 43 1 45 9 46 2 47 9 50 0 48 8 49 1 53 3 53 0 C...

Страница 6: ...n TESTING PRESSURE Pressure test 3 3MPa for 1 minute Leakage test 1 6MPa for 5 minutes TUBE MATERIAL COPPER DIAMETER mm 9 52 in 3 8 THICKNESS mm 0 3 in 0 012 FIN MATERIAL ALUMINIUM THICKNESS mm 0 11 i...

Страница 7: ...20 46 9 21 30 40 41 41 38 32 24 46 6 MEDIUM 21 31 40 42 41 38 28 19 46 5 21 31 40 41 40 38 31 23 46 2 LOW 18 29 38 40 39 35 25 16 44 4 20 30 38 40 38 36 28 19 44 6 600D HIGH 22 31 41 42 43 40 30 20 4...

Страница 8: ...5 14 5 3 4 2 4 0 344 15 8 MCW500D 75 24 0 17 9 5 5 14 5 3 8 2 7 0 389 7 2 MCW600D 75 24 0 17 9 5 5 14 5 5 0 3 7 0 482 11 4 MCW800D 75 24 0 17 9 5 5 14 5 6 2 4 6 0 618 10 0 MCW900D 75 24 0 17 9 5 5 14...

Страница 9: ...783 1651 1536 1420 1408 1347 1241 1120 L 1496 1413 1365 1281 1233 1143 1096 1088 1002 892 900D H 2197 2113 2027 1920 1795 1683 1622 1560 1455 1325 M 2078 1994 1902 1814 1685 1586 1538 1477 1370 1247 L...

Страница 10: ...ING LIMITS Maximum water side pressure 16 bar Minimum entering water temperature 3 C Maximum entering water temperature 95 C Minimum air inlet temperature 5 C Maximum air inlet temperature 43 C Power...

Страница 11: ...30 40 50 60 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 Water Flow m 3 h Water Pressure Drop kPa 400D 300D 200D 600D 500D 900D 800D 1400D 1200D 1000D Note The press...

Страница 12: ...51 94 143 218 2 902x244x25 2 600D 1214 1314 984 948 987 1047 534 150 251 94 143 218 2 1002x244x25 3 800D 1464 1564 1234 1198 1237 1297 534 150 251 94 143 218 3 1252x244x25 3 900D 1564 1664 1334 1298 1...

Страница 13: ...series H M L are connected to SHF HF MF respectively MODEL MCW 200 1400 POWER SOURCE ORANGE DRAWING NO M08024067082 N L MF LF SHF HF L M BROWN H YELLOW FAN BLACK FAN SPEED SWITCH NOTE MOTOR 1 BLACK F...

Страница 14: ...to the carrier with a formal claim LOCATION Before installation please check the following 1 There must be enough space for unit installation and maintenance Please refer to the unit s drawings and di...

Страница 15: ...IPE CONNECTION 1 Using suitable fittings as water pipe connections Refer to the specification 2 The water inlet is on the bottom while outlet on top 3 The connection must be concealed with rubberized...

Страница 16: ...15 Exploded view Part List 8 FAN 6 FILTER 7 MOTOR 2 FANDECK 4 PLENUM 1 TOP PLATE 3 DRAIN GUIDE PLATE 5 COIL 9 DRAIN PAN 10 HEDER OUTLET 11 HEADER NLET...

Страница 17: ...4061142 M02124061198 M02124061198 MODEL 800D 900D 1000D 1200D 1400D 1 TOP PLATE PART NO M01014060796 M01014060797 M01014060798 M01014060796 M01014060798 2 FAN DECK PART NO M01014060806 M01014060807 M0...

Страница 18: ...amless copper tubes slit type aluminum blue fins bonded to the tubes by mechanical expansion Each coil has a manual air vent and two Rc3 4 water pipe connections with a working pressure of 1 6MPa 3 Fa...

Страница 19: ...ect at the time of going to press we are constantly striving for improvement and therefore reserve the right to alter model specifications and equipment without notice Details of specifications and eq...

Отзывы: