McQuay LDD Скачать руководство пользователя страница 11

IM 439 / Page 11 of 24

Figure 13. Typical Mark IV/AC unit — dual compressor

L1

L2

L3

COMMON

COMP

FAN

O

W

G

WY

FE

L

U

A

P

V

R

C

21

1

COMMON

COMP

FAN

O

W

G

WY

FE

L

U

A

P

V

R

C

21

1

Fan

Motor

Electric

Expan V

alve

Optional

Crankcase

Heater

Compr

. 2

C

ompr

. 1

Chassis

Control

RD7

BK12

RD6

BK92

BK93

Compr

.

Cont. 1

Compr

. Cont. 2

BK82

BK83

}

YE14

Optional

Positive

Staging

Relay

GR/YE

YE13YE13

BK1

1

BK

RD

YE

WH

WH56

WH

WH57

WH55

Circuit 2

Thermistor

Thermistor

Electric

Expan V

alve

WH

WH46

WH

WH47

WH45

Low T

e

mp

Circuit 1

2

1

2

1

Circuit

     1

Circuit

     2

High Press

Switch

Low Press

Switch

Reversing V

a

lve

Solenoid

(not required on cooling only)

<<

<<

<<

<<

<<

<<

<<

<<

High Press

Switch

Low Press

Switch

BK

WH

BK

WH

BR

BR

BL

BL

BR53

Low T

e

mp

BR

BR

BL

BL

RD54

BR52

BK51

BL50

BL40

BK41

BR43

RD44

BR42

BK51

BL50

BL40

BK41

YE

<<

<<

Condensate

Overflow

Sensor

BK30

BK49

RD48

BK

BK

BK59

RD58

BK

BK

1

2

5

3

4

BR87

RD88

PK89

WH85

WH86

BK83

BL18

YE13

BK1

1

BK82

BK31

YE8

BK4

BK

WH

RD

OR

YE14

BK12

BK92

BK32

YE9

BK5

WH

RD

OR

BK93

BL17

BK

BK

RD

YE

BK10

RD208

OR240

RD208

OR240

BL

YE

BK

BL

YE

BK

WH16

YE28

YE23

WH16

BK34

BL19

Control 1

BR42

BR43

BK41

BK40

BK30

BK29

WH66

BL50

BK51

COF

LT
LT

HP
HP

BK24

BK25

RV

RV

V

R

C

Red

3

1

2

4

Red

Red

Red

3

1

2

4

Control 2

BR52

BR53

COF

LT
LT

BK20

RV

RV

V

R

C

HP
HP

BK19

WH56

PK21

YE23

WH64

RD22

WH55

BK59

RD59

BR53

BK51

BL50

BK29

PK89

BR87

RD88

WH46

PK26

YE28

WH65

RD27

WH45

BK49

RD48

WH15

BL17

BK33

GND

Breaker 3A

 (optional)

Field

Line

Vo

lt

age

WH15

YE3

BK10

RD2

BK1

BK34

BK33

YE3

YE8

YE9

RD7

RD2

RD6

BK4

BK1

BK5

BK

YE

RD

BL

BL

RD27

RD22

Содержание LDD

Страница 1: ...tallation Maintenance Data IM 439 15 Group WSHP Part Number 106581103 Date June 2006 Large Vertical Water Source Heat Pumps 6 thru 25 Tons Models LDD LDE LDL LDS LME LMH LML LMS 2006 McQuay Internatio...

Страница 2: ...xt Range LMH High Static Large Vertical Mark IV Std Range LDL Std Large Vertical DDC Controls Ext Range Less Board LML High Static Large Vertical Mark IV Ext Range LDS Std Large Vertical DDC Controls...

Страница 3: ...on submittal drawings 7 The installing contractor will find it beneficial to confer with piping sheetmetal ceiling and electrical foremen together before installing any conditioners Note Check the un...

Страница 4: ...2 114 mm 51 2 140 mm 25 8 61 mm Figure 2 Side view from piping end Each unit is shipped with a filter bracket for side filter removal Two fan discharges and piping arrangements are available With the...

Страница 5: ...pitch diameter for desired speed by open ing moving parts by half or full turns from closed position Do not open more than five full turns 3 Replace external key E and securely tighten setscrews B ove...

Страница 6: ...ication limits It is also general practice to close off the ventilation air system during unoccupied peri ods night setback The ventilation air system is generally a separate build ing subsystem with...

Страница 7: ...he union one to hold the line and one for simultaneous tightening of the nut 4 Supply and return shutoff valves are required at each con ditioner The return valve is used for balancing and should have...

Страница 8: ...ermostat to Cool If the thermostat is an automatic changeover type simply set the cooling temperature to the coolest position On manual changeover types addi tionally select Cool at the system switch...

Страница 9: ...e with local codes or the National Electrical Code whichever is applicable 2 Apply correct line voltage to the unit Each unit is supplied with a 3 lug terminal block in the main control for three phas...

Страница 10: ...BK 21 15 Fan Motor GN GND YE RD BK Common Comp Fan Mark IV AC Board Compressor Contactor 36 35 21 L1 37 37 Breaker Optional OR 230V RD 208V BK RD 460V BK BK YE GND Xformer REV Valve Solenoid COF LT L...

Страница 11: ...itch BK WH BK WH BR BR BL BL BR53 Low Temp BR BR BL BL RD54 BR52 BK51 BL50 BL40 BK41 BR43 RD44 BR42 BK51 BL50 BL40 BK41 YE Condensate Overflow Sensor BK30 BK49 RD48 BK BK BK59 RD58 BK BK 1 2 5 3 4 BR8...

Страница 12: ...troller 68 67 66 65 64 63 62 1 2 3 4 5 6 7 11 10 9 8 7 6 5 4 3 2 1 J6 2 3 4 5 7 8 9 10 11 J5 J4 Low Temp SIG Lo Press SIG Condensate Lo Temp SRC RV Out Comp Com Comp Out Fan Com Fan Out 24VAC 24V Gnd...

Страница 13: ...3 4 1 2 3 4 1 J2 J1 2 1 46 Disch Air Water Out 44 42 43 Condensate Lo Temp SRC Lo Temp SIG Lo Press SIG Lo Press SRC Hi Press SIG RV Com RV Out Comp Com Comp Out Fan Com Fan Out 24VAC 24V Gnd Dischar...

Страница 14: ...he reversing valve is set up to be energized in the heating mode The circuit board has a fan interlock circuit to energize the fan whenever the compressor is on if the thermostat logic fails to do so...

Страница 15: ...s of the standard thermostat are then connected to the Mark IV AC board thermostat inputs and control inputs as needed Any re maining board input s may be operated by additional thermostat out puts or...

Страница 16: ...application guide LIA217 for thermostat 107095901 installation details WSHP Mark IV AC Board Low Voltage Terminal Strip Circuit1 O W2 G W1 Y1 F E L U A P V R C R C W1 Y1 W2 Y2 G Thermostat Terminals W...

Страница 17: ...t Sizes 180 to 290 Non Programmable Electronic Thermostat 2 Circuits P N 107095901 7 Day Programmable Electronic Thermostat 2 Circuits P N 107095901 Includes Thermostat and Wall Plate Refer to the ins...

Страница 18: ...ressor operation is required the Mark IV AC P terminal will change state causing a contact closure between terminal 58 and 64 signaling the loop water control LWC panel to restart the loop pump if Off...

Страница 19: ...wn below can only be used when the P terminal is not being used as a pump restart signal to other equipment If the P terminal must be used as a pump restart signal to other equipment then wire the aux...

Страница 20: ...kit you attach the sheet metal enclosure to the unit as shown route the 4 wire harness through knockouts and connect to the Mark IV AC board mount and connect and insulate the water tempera ture senso...

Страница 21: ...rmally open contacts will close Operation In this example the auxiliary relay is used to interface other control devices to the Mark IV AC board Using the Orange and White wires and 24vac or 24vdc ano...

Страница 22: ...ot required 3 Fresh Air Damper These outputs provide a signal that can be used to control a remote fresh air damper The output will energize when the unit fan is energized and de energize when the uni...

Страница 23: ...eating Check compressor wiring for defective wiring or loose connection Check thermostat for improper location Check for defective compressor internal windings with ohm meter Check for bad compressor...

Страница 24: ...s will depend upon the project requirements Some applications such as motels produce a lot of lint from carpeting and linen changes and will require more frequent filter changes It is suggested that t...