653-041
P2008 © Firma WJG, Braunschweig. Nachdruck oder Vervielfältigung nur mit ausdrücklicher Genehmigung
[DAY]: Day of the week indicator.
[HEAT ON]: Shows that the heater is active.
[AIR-CONDITIONING ON]: Shows that the air-conditioner is active.
[CT]: Shows that the CT-temperature-mode is active.
[ET]: Shows that the ET-temperature-mode is active.
[(CT) PERIOD]: Indicates the period of time in which the CT-mode is active.
[(ET) PERIOD]: Indicates the period of time in which the ET-mode is active.
[TIME]: The current time.
[MANUAL OVERRIDE]: Shows that preset values are overridden by manual setting.
[BATTERY LOW INDICATION]: Indicates that the batteries are low.
[VACATION]: Shows that the energy-saving-mode is active.
[TEMP.]: The current room temperature.
[PROGRAM SCHEDULE]: Indicates the period of time a preset value is active.
Adjustment of the current Time and the Day of the Week:
•
As soon as the batteries are inserted the template for adjusting the current time opens. If not just press
CLOCK or RESET.
•
The hour digits flash and you can adjust the time by using INCREASE and DECREASE. Then confirm the
input with Ok/ENTER.
•
Now the minute digits flash and you can adjust the time by using INCREASE and DECREASE. Then
confirm the input with Ok/ENTER.
•
Now the day of the week display flashes. Here also you can adjust it by using INCREASE and
DECREASE. Then confirm the input with Ok/ENTER.
•
After that you will return to the running mode.
•
If you want to set up the current time in between you can open this template by pressing CLOCK or
RESET.
Adjustment the Regulation Periods and their Temperatures:
•
Press PROGRAM to enter the adjustment-menu.
•
The thermostat comes with the factory presetting: Mo – Fr 6:00 pm – 7:59 pm & 4:00 pm – 10:59 pm
and Sa – Su 7:00 am – 10:59 pm are CT-mode-periods with 20°C room temperature when using a
heater and an air-conditioner will be activated at 23°C. Mo – Fr 11:00 pm – 5:59 am & 8:00 am – 3:59
pm and Sa – Su 11:00 pm – 6:59 am are ET-mode-periods with 17°C room temperature when using a
heater and an air-conditioner will be activated at 28°C.
•
The adjustment-menu starts with the template of Monday and jumps to the next day every time you
press OK/ENTER. After the Sunday setting is confirmed you will return to the running mode.
•
If you like to change the ET-periods just go to the desired hour on the desired day. Here you can
change every single value by pressing CT. If you like to change the CT-periods just go to the desired
hour on the desired day. Here you can change every single value by pressing ET. Finally presses the
OK/ENTER to confirm the setting and to return to the running mode.
•
For adjusting the temperatures of the CT- as well as the ET-periods first press TEMP. and choose CT or
ET. Now adjust the desired temperature with INCREASE or DECREASE. Finally confirm with OK/ENTER
and return to the running mode simultaneously.