background image

                                             
                                                            www.mcohome.com                                          User Manual                                                           

                              4

 

   

0x03 

ALL ON/ALL OFF   

0x00 forbid ALL ON, forbid ALL OFF 

0x01 forbid ALL ON, allow ALL OFF 

0x02 allow ALL ON, forbid ALL OFF 

0xFF allow ALL ON, allow ALL OFF 

0xFF 

 

0x04 

LED Backlit 

brightness level 

0x00 LED disabled 

0x01~0x0A Min level-Max level 

>0x0A same level as 0x0A 

0x0A 

 

0x05 

Key Mode 

0x00 single click to switch on/off status 

0x01  Key  default  as  off  state.  When  it  is 

turned  on,  then  it  will    be  turned  off 

automatically  after  a  time period  , which 

can be set in item 0x06 

0x02  Key  default  as  on  state.  When  it  is 

turned  off,  then  it  will    be  turned  on 

automatically  after  a  time period  , which 

can be set in item 0x06 

0x03 hold >3s then key is on, and off once 

released 

0X04 single click to switch on/off  

hold  >3s  then  key  is  on,  and  off  once 

released 

0x00 

This function 

works for 

corridor or 

stairwell 

situation.   

0x06 

Key On duration 

0x00 infinite 

1~65535    unit "sec" 

0x00 

 

0x08 

Basic CC integration 

setting 

0x00 "Basic Set" received

key 1 responds; 

"Basic Get" received

key 1 sends "Basic 

Report"; key 1 will not send unsolicited 

"Basic Report"

No Endpoint

to LifeLine 

Association 

0x01 "Basic Set" received

key 1 responds; 

"Basic Get" received

key 1 sends "Basic 

Report"; key 1 will send unsolicited "Basic 

Report"

No Endpoint

to LifeLine 

Association 

0x02 "Basic Set" received

all keys   

respond;    "Basic Get" received

not reply 

"Basic Report";    All keys will not send 

unsolicited "Basic Report"

No Endpoint

to LifeLine Association 

0x03 "Basic Set" received

all keys   

respond;    "Basic Get" received

key 1 

sends "Basic Report";    All keys will not 

send unsolicited "Basic Report"

No 

Endpoint

to LifeLine Association 

0x00 

This parameter 

works for 

integration with 

different 

gateways/syste

ms. If do not 

know how to 

use, pls keep as 

default. 

Отзывы: