www.mcohome.com User Manual
MCOHome Technology Co., Ltd 2013
4
Monitoring Energy Consumption
When requested by controller or gateway, the Mini Energy Dimmer will report immediate voltage,
current, power, and energy consumption (the command classes which support this function is
Meter Command Class). When set unsolicited report, the module will send data to association
group 1 at regular time.
Parameter Number
0x02
Size
1 BYTE
Default value
0x00
Configuration value
Bit 0: KWH Report
Bit 1: Voltage Report
Bit 2: Current Report
Bit 3: Watt Report
(Bit Set to 1: enable 0:disable)
The interval time can be set as follows:
Parameter Number
0x03
Size
2 BYTE
Default value
0x0258 (10 minute)
Configuration value
0~65535 sec
Setting & Activating Scene
The module can set and activate 255 scene IDs by using gateway and scene controller. The
“SCENE_ACTUATOR_CONF_SET” in “COMMAND_CALSS_SCENE_ACTUATOR_CONF” is used to set
scene, and “SCENE_ACTIVATION_SET” in “COMMAND_CLASS_SENE_ACTIVATION” is used to
activate scene. Please refer to instructions provided by controller manufacturer for details.
Restoring Factory Settings
The default configuration can be restored by:
Sending commands through controller or gateway (the command classes which support this
function is Configuration Command Class). The parameter are as follows:
Parameter Number
0xFF
Size
1 BYTE
Default value
N/A
Configuration value
0x55
Set 0xFF as 0x55 will restore Factory Settings.
Pressing and Holding the ON/OFF/PROGRAM button for 15s.
Note
:
If the Factory Settings is restored successfully, INDICATION LED will blink quickly and then
become slower.