                                                            Technical Parameters                                                                                                                                   

 

 

Power Supply: AC24V 

 

Resistive Load:

1A

 

 

Self-Consumption: <2w 

 

Thermistor: NTC thermistor 

 

Temp. Setting Range

10-35℃(50~95℉) 

 

Precision

0.1℃(1℉) 

 

Outcase

Tempered glass + PC 

 

Dimension

102*102*20mm 

 

Installation

60mm or 82mm hole pitch 

 

Active Element: Relay switch μ 

 

Maximum Transmitting Power: +3dBm 

 

Z-Wave Frequency: Operating frequency range, defined by the regulatory bodies (for Z-wave in Europe: 868.0      - 

868.6    MHz, 869.7 - 870.0 MHz)   

 

Over Current Protection: Required external 10A circuit breaker

                                                                      Features                                                                                         

 

 

Application range: gas/fuel boiler, electric heating, water heating, heat pump etc. 8 types control systems. 

 

4.3’’ LCM display, touch screen operation interaction. 

 

Simpler way to connect wires without screw driver. 

 

7days 4 time periods scheduling. Set the target heating and cooling temperature respectively. 

 

Schedule, hold modes for different situations. 

 

 

 

 
 
 
 

 

Declaration of Conformity 

MH-F500 Thermostat User Guidance

                                                 

Introduction 

 

MH-F500 thermostat is used to control up to 3 stages heating 
and 2 stages cooling system with 8 types control system, EM 
heat activation, adjustable compressor delay time and O/B 
changeover. It is with tempered touch sensitive screen, quick 
connecting terminals to save installer’s time. 7days 
programmable and four modes everyday make users’ life 
convenient and comfortable. 

Содержание MH-F500

Страница 1: ...c heating water heating heat pump etc 8 types control systems 4 3 LCM display touch screen operation interaction Simpler way to connect wires without screw driver 7days 4 time periods scheduling Set t...

Страница 2: ...reach of children and animals Do not expose the device to moisture water or other liquids Do not place liquids near or on the device Do not attempt to disassemble repair or modify the device yourself...

Страница 3: ...n Instruction REQUIRED 24VAC POWER C WIRE Set system status 3 Wires Connection Instruction WIRE Display Functions Settings Set system status Wires Connection Instruction Display Functions Settings Set...

Страница 4: ...pper level setting interface without storing the changes Please check the following figures Set working mode The device provides two modes for the users Scheduling Hold Press Menu Next until the displ...

Страница 5: ...ress Done A node ID can always inform us whether the device is in the network or not Set schedule provides 4 times periods each day 7days for both heating and cooling status times SCHEDUL SET Edit Pre...

Страница 6: ...0 28 82 HEAT Mode 6 00 25 5 78 8 00 29 5 85 18 00 25 5 78 22 00 28 82 User Setup Press Menu Next press 4times USER SETUP Edit Temperature Scale TEMP SCALE Press to change between and Schedule for HEAT...

Страница 7: ...erence Press deleted the value Range 0 5 2 to set the brightness of the screen 0 Only display current indoor temperature in half brightness 1 Display all contents in half brightness 2 Display all cont...

Страница 8: ...ol O B Change over logic 8 to set the value OFF 5s 15s 30s OFF the fan not delay 5s the fan will delay 5s 15s the fan will delay 15s 30s the fan will delay 30s Setup Press Menu Next press 5times FACTO...

Страница 9: ...the outdoor temperature is extremely low so as to protect the outdoor unit CHANGE OVER When change over is ON the device will start heating or cooling automatically according to the desired temp When...

Страница 10: ...ice supports S2 function 2 Z WAVE supported Command Class COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_VERSION COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_ASSOCIATION COMM...

Страница 11: ...value set by parameter 4 COMMAND_CLASS_THERMOSTAT_MODE_V2 THERMOSTAT_MODE_REPORT Thermostat mode changes COMMAND_CLASS_THERMOSTAT_OPERATING_STATE THERMOSTAT_OPERATING_STATE_REPORT Thermostat status c...

Страница 12: ...LIMITED WARRANTY DOES NOT COVER ANY DAMAGE TO THIS PRODUCT THAT RESULTS FROM IMPROPER INSTALLATION ACCIDENT ABUSE MISUSE NATURAL DISASTER INSUFFICIENT OR EXCESSIVE ELECTRICAL SUPPLY ABNORMAL MECHANIC...

Отзывы: