06-10-2020 14
:
09
Pagina 3 van 5
http://manuals-backend.z-wave.info/make.php?lang=en&sku=MCOETPS412&cert=&type=mini
Setting
Description
0
not saved
҅
switch will be off when powered again
1
saved
҅
switch will keep the same state when powered again
Parameter 3: ALL ON/ALL OFF
Size: 1 Byte, Default Value: 255
Setting
Description
0
forbid ALL ON, forbid ALL OFF
1
forbid ALL ON, allow ALL OFF
2
allow ALL ON, forbid ALL OFF
255
allow ALL ON, allow ALL OFF
Parameter 4: LED Backlit brightness level
Size: 1 Byte, Default Value: 10
Setting
Description
0
LED disabled
1 - 10
Min level-Max level
Parameter 5: Key Mode
This function works for corridor or stairwell situation.
Size: 1 Byte, Default Value: 0
Setting
Description
0
single click to switch on/off status
1
Key default as off state. When it is turned on, then it will be turned off automatically after a time period , which
can be set in item 6
2
Key default as on state. When it is turned off, then it will be turned on automatically after a time period , which
can be set in item 6
3
hold >3s then key is on, and off once released
4
single click to switch on/off hold >3s then key is on, and off once released
Parameter 6: Key On duration
Size: 2 Byte, Default Value: 0
Setting
Description
0
infinite
1 - 65535
unit sec
Parameter 8: Basic CC integration setting
This parameter works for integration with different gateways/systems. If do not know how to use, pls keep as default.
Size: 1 Byte, Default Value: 0