background image

06-10-2020 14

:

09

Pagina 3 van 5

http://manuals-backend.z-wave.info/make.php?lang=en&sku=MCOETPS412&cert=&type=mini

Setting

Description

0

not saved

҅

switch will be off when powered again

1

saved

҅

switch will keep the same state when powered again

Parameter 3: ALL ON/ALL OFF

Size: 1 Byte, Default Value: 255

Setting

Description

0

forbid ALL ON, forbid ALL OFF

1

forbid ALL ON, allow ALL OFF

2

allow ALL ON, forbid ALL OFF

255

allow ALL ON, allow ALL OFF

Parameter 4: LED Backlit brightness level

Size: 1 Byte, Default Value: 10

Setting

Description

0

LED disabled

1 - 10

Min level-Max level

Parameter 5: Key Mode

This function works for corridor or stairwell situation. 

Size: 1 Byte, Default Value: 0

Setting

Description

0

single click to switch on/off status

1

Key default as off state. When it is turned on, then it will be turned off automatically after a time period , which
can be set in item 6

2

Key default as on state. When it is turned off, then it will be turned on automatically after a time period , which
can be set in item 6

3

hold >3s then key is on, and off once released

4

single click to switch on/off  hold >3s then key is on, and off once released

Parameter 6: Key On duration

Size: 2 Byte, Default Value: 0

Setting

Description

0

infinite

1 - 65535

unit sec

Parameter 8: Basic CC integration setting

This parameter works for integration with different gateways/systems. If do not know how to use, pls keep as default. 

Size: 1 Byte, Default Value: 0