8
2.3.1 ARM (for automatic activation by immersion in water)
To set the Watch in ARMED mode:
Step 1: Press the CONFIRM button 3 times:
A single beep and LED flash confirms this step.
Step 2: Press the ARMING button once:
The acknowledgement is a double beep and LED flash.
Once armed the LED will flash once every minute or so to indicate that it is in ARM mode.
2.3.2 DISARM
To DISARM the Watch:
Step 1: Press the CONFIRM button 6 times:
A single beep and LED flash confirm this step.
Step 2: Press the ARMING button once:
The acknowledgement is a double beep and LED flash.
2.3.3 Water Sensor
The housing has 2 stainless steel sensors that are exposed on the outside of the
main housing. For activation, the beacon must be submerged in water for at least 4
seconds. The Water Activation Sensor functions only when the beacon is in the
ARMED mode.
NOTE:
The beacon may activate automatically in extremely damp or wet
conditions. If this occurs, use the beacon in Manual Transmit mode.