Page 28
3.9. Reset the Run Time counters on the PCB
The Smartfind PCB records the following during the life of the unit:
1. Number of long GPS tests carried out
2. Run time of 406MHz transmissions.
3. Run time of unit including self test.
These counters must only be reset after a battery change
.
The utility is available as a stand alone programme (Smartfind Factory Reset).
Note: Carrying out this reset does not alter any of the other programmed information.
Procedure:
1. Plug the USB pen into the USB port of the computer.
2. Open ‘Smartfind Factory Reset’ software program.
3. Select the com port.
4. Press ‘Reset Beacon’
5. Ensure Tx LED flashes on side of pen.
6. Hook the pen into position on the EPIRB.
7. Press and release the TEST button on the EPIRB.
8. The red ‘Reset in progress’ and yellow ‘IR link active’ indicators will light.
9. The EPIRB will emit a number of beeps to indicate reset in progress.
10. The green ‘Factory reset complete’ indicator will light to indicate successful reset.
If the unit is flashing the strobe less than 3 times after carrying out the above reset, the
run time counters have not been reset.
Check to confirm the firmware version: if is 82-850Z version 1.2.186 then the PCB will
need to be upgraded.