Commercial in confidence
Smartfind EPIRB service manual
Page 12
3. MAINTENANCE PROCEDURES
3.1. Inspection
Manual bracket (carry safe)
If this has been returned, it should be checked as follows:
Magnet
Confirm magnet is still potted into bracket and is not rusting
Release clip
Check for correct and smooth operation.
R-clip should engage.
Carry safe
carry safe section should disengage from main bracket.
Automatic bracket (Enclosure/Autocover)
If this has been returned, check it as follows:
Cover intact
Ensure offset weight is secure.
Check cover retaining pin is present and attached to cover.
Confirm identity label on side agrees with rear of EPIRB.
Lever arm
Check magnet present.
Release HRU (press down and slide upward)
Confirm lever arm moves freely and is secure.
HRU expiry date
Side of HRU should be marked with expiry date.
Confirm date is acceptable.
If less than 3 months left, recommend a new HRU to customer
Confirm HRU expiry date is marked on cover side label.
Press lever arm down and refit the HRU. Ensure washer engages (section 3.10).