Keypad -
Indicators
Section Lights-
There are 8 or 24 section lights on the command centre.
-
When the system is in the
OFF
mode all non 24 hour
sections are not armed and the Section Lights indicate
the condition of the sensor..When the Section Light is
On the sensor is activated (e.g. door contact detecting
door open or motion detector sensing movement).
When the Section Light is OFF the sensor is not activated.
-
When the system is in the
ON
mode all non isolated sections
are armed. If the section light is FLASHING the sensor is
activated and triggers the siren and strobe light (if it is not
silent).This alarm is transmitted to the central station. When
the light is out the section is not activated.
-
When the system has been Armed, an exit timer starts and
holds the sections that have been programmed for Exit or
Entry delay disarmed. This allows the user to exit the
premises
without
activating
the
alarm.
-
When the system is armed, and the Exit timer has fi nished,
Entry into the premises can be made via a section that has
Entry delay. This starts the Entrydelay and if the system is
disarmed there will be no alarm.
Power Light
-
This light is normally ON. This indicates that the Plug Pack
power and backup battery are normal.
-
When the Plug Pack power is not good (i.e. the mains has
failed) the power light will single fl ash.
-
When the Plug Pack power and battery are not good, the
power
light
will
double
fl ash.
Program Light
-
Flashing while in Program mode. Program mode is entered
when a user code is entered and isolate or test modes are
selected. Program mode is also selected when the master
code is entered and the user codes are being viewed or
changed.
-
When not in program mode the Program Light is Off